Selecting the right industrial flooring for your needs can be a complicated undertaking. Besides the obvious considerations of colour and material, there may be specific performance requirements to take into account, particularly when the area may be used for highly sensitive operations such as healthcare or delicate manufacturing processes.

For a wide range of industries, one critical consideration is whether a floor needs to be anti-static. Determining that answer is just the first step: if you need anti-static flooring, you also need to know the types available, the benefits and the options to consider when choosing an anti-static floor provider.

 

What Is Anti-Static Flooring?

Anti-static industrial floors inhibit the generation of electrostatic discharge or ESD, which is the pulse of static electricity that happens when a charged person or surface comes into contact with another object. The discharge may be visible as a spark or tiny blue bolt of electricity, although the majority of static electricity is not usually apparent.

We commonly refer to ESD as getting a shock off an object or person, and in most instances, the static discharge is harmless, even if it hurts slightly when it occurs. In certain environments, however, an electrostatic discharge can be highly dangerous and potentially even catastrophic. In those cases, installing anti-static flooring is an essential step in creating a safe environment for workers and visitors.

Who Needs Anti-Static Floors?

While many organisations may consider anti-static flooring options for a variety of reasons, certain industries require anti-static floors as a most basic safety precaution. Chemical manufacturers and processors, as well as any businesses that may use flammable chemicals or materials in their operations, need to create static-free work environments to avoid igniting chemicals, fumes or even microscopic flammable particles. Electrostatic discharge can render sensitive electronic components useless, so organisations involved in the production or assembly of semiconductors or electronic goods need anti-static floors.

Additionally, any operations that rely on uninterrupted or guaranteed use of specialised electronic items, such as hospitals or air-traffic control rooms, should take precautions to avoid static. Other examples of industries that require anti-static flooring include munitions or pyrotechnics manufacturing, military operations, micromechanics, optical lenses, photographic film, lasers, biotechnology, pharmaceuticals, surgical implant manufacturing, medical environments and even some food and beverage production environments.

 

How Does Anti-Static Flooring Help?

Anti-static floors help by taking the static electricity that builds up naturally in any environment and moving it through the floor to ground. By grounding the charge, anti-static flooring prevents the ESD from building up and discharging into the environment, where it could be destructive to goods or dangerous to people.

Almost any movement within an environment will contribute to the static electricity present, whether its the familiar walking across a carpet in an office, the everyday movement of vehicles or heavy equipment over a warehouse floor or the repetitive movement of parts of an automated machine in a factory. That majority of electrostatic discharges are below 3,500 volts and totally undetectable to people, so were not even aware of most of the potentially dangerous ESD happening all around us. Anti-static flooring, however, is capable of capturing all those charges and grounding them before they cause reactions.

 

How to Select Anti-Static Floors

Just as there are many uses for anti-static flooring, there are also many choices to consider when choosing an anti-static floor. The first step is to understand the risks and requirements for your specific use case, including how electrostatic energy is generated in your location, the estimated strength of your average ESD and the potential consequences of electrostatic discharges in your facility. Next, its important to understand the subtle but important differences in static control terminology to help you decide which type of anti-static flooring is right for you.

The resistance or impedance of anti-static flooring is expressed in ohms (Ω), a unit of measurement named after Georg Ohm, the German physicist who discovered Ohms Law, which governs electrical currents through conductors. Anti-static flooring options include conductive and dissipative systems, which offer different ranges of electrical resistance; in general, conductive flooring offers a resistance of up to 1 mega Ω, and static dissipative flooring provides resistance between 1 mega Ω and 100 mega Ω.

In simple terms, higher resistance equals lower conductivity of energy; however, that doesnt mean that lower resistance is necessarily the better option for anti-static floors. In fact, in most mission-critical environments like emergency call centres or air traffic control towers, grounding standards recommend static dissipative flooring over conductive flooring options. The right choice for you really depends on your specific needs.

Choosing a Solution and Provider

Regardless of which anti-static flooring solution you choose, professional and knowledgeable installation will make a big difference in the success and longevity of your floor. It is important to choose a provider or contractor based on their experience and reliabilitynot because of their lower price. The total cost of ownership of any industrial floor, whether anti-static, resin, concrete or carpet, does not end with the installation. There are maintenance and repair to think of, which means warranties and quality matter. Check out the company providing the solution, including their history and reputation; no one worthwhile will fault you for being thorough in your flooring consideration.

 

Equally important is a thorough understanding of the maintenance requirements and potential repair costs of your anti-static floors. Epoxy anti-static floors cannot be overlaid as this will insulate the floor from the earthing points so the epoxy must be first removed back to the substrate, with new copper strips installed for re-earthing and grounding. The new epoxy coating is then installed with an additional 7 days before the epoxy fully cures. Vinyl flooring will have a shorter life expectancy and a lower abrasion resistance resulting in the need for maintenance and ultimately replacement in a far shorter period. Conversely, PMMA resin flooring can be reverse-cured, which makes spot repairs easy to do. Get to know the needs of the floor types youre considering and factor the expected costs of maintenance and repairs into your budget to get a true picture of how much a solution will cost.

 

Verifying Sub-Floor Conditions

The success of any anti-static flooring solution is largely dependent on the quality of the site in which it is installed. Contaminated concrete or moisture problems can lead to ineffective and even problematic flooring. Most issues can be solved ahead of installationprovided you are aware of them. Flooring manufacturers and certified contractors will be able to arrange for your sub-floors to be tested ahead of installation to help ensure the success of your anti-static floors.

 

Protective, Safe and Practical Anti-Static Flooring

Todays most advanced options for anti-static flooring are also the most simplified. Trazcon anti-static dissipative flooring offers an electrical resistance of ×106Ω < RE < 1×108Ω, making it an ideal solution for a wide range of anti-static flooring needs. Whereas traditional anti-static flooring was made up of a primer, copper strips, independent wiring and an epoxy coating that took seven days to fully cure (harden), Trazcon anti-static contains an anti-static filler powder in the seal coat and boasts an industry-leading one-hour cure time. Not only is the floor ready for use just one hour after installation, but any necessary repairs can be made without digging up large sections of the floor or cutting channels for regrounding. As Trazcon anti-static is a dissipative floor there is no requirement for copper strips or earthing points.

 

Floortech is the specialist provider of the PMMA anti-static flooring solution, which is highly recommended for laboratories, production areas, material testing zones, service workshops, automotive facilities, and electronic component areas.  Our Trazcon® Anti-Static system is suitable for use in AtEx zones, offering protection for the storage of flammable liquids, gases, vapours and mist, as well as combustible clouds of dust.

 

For specifics about PMMA anti-static flooring, download the technical data sheet available from Floortech or contact our team of experts.

 

Antistatic and ESD flooring: standards and testing methods

Floors which help prevent damage due to electrostatic discharge (ESD) must be specified, installed and tested according to the relevant standards. Rather than relying on terms such as antistatic, ESD or conductive to describe such floors, specifiers should define the resistance that the floor should provide, and details on how it should be tested before it is selected and after it is laid.

In previous blogs, we explained why antistatic (AS) and ESD floors are increasingly in demand (Is your shop floor prepared for a smart world?) and how such specialist flooring works (How does flooring from Master Builders Solutions help to control static discharge?). In this post we will look at the relevant standards and outline the most common testing methods deployed.

Which standard, which resistance?

There are multiple reasons why an antistatic or ESD flooring may be required. Here we outline the relevant situations, which regulations or codes govern them and elaborate on the electrical properties or electrical behavior that may be necessary for flooring in each situation.

Potentially explosive environments are covered by two European directives known as the ATEX (EXplosive ATmospheres) Directives:

NFJ Product Page

  • ATEX 214 equipment Directive /34/EU Equipment and protective systems intended for use in potentially explosive atmospheres.

  • ATEX 137 workplace Directive /92/EC Minimum requirements for improving the safety and health protection of workers potentially at risk from explosive atmospheres.

Floors in these environments should have the following Resistance to ground (Rg), when measured according to EN or IEC -4-1:

Between 104 Ω and 106 Ω (below 5 x 104 Ω in special cases such as explosives manufacture).

ESD Protected Areas (EPAs), where electronic elements should be protected to prevent damage to equipment and to provide safety, are covered by the international specification IEC -5-1 which says:

  • If flooring is not used to ground people handling electronically sensitive devices, Rg < 109 Ω.

  • If flooring is used to ground people, different resistance measurements have to be specified and tested: person/footwear/flooring system Rg < 109 Ω and body voltage generation < 100 V.

Clean rooms, used for research or as production rooms for pharmaceuticals for instance, tend to have specifications that follow either ATEX or EPA guidelines.

Rooms with electrical installations, where people or livestock require protection from electrical shocks, require flooring with a minimum resistance set by IEC Electrical Installations for Buildings Part 4, section 41:

  • Rg > 50 kΩ, for a nominal voltage of the site < 500 V.

  • Rg

    > 100 kΩ, for a nominal voltage of the site > 500 V.

Which testing method, when?

There are three standards that contain the most relevant test methods for AS and ESD flooring:

  • EN :+A1: Resilient floor coverings determination of the electrical resistance.

  • Various parts of the IEC series of Electrostatics standards (IEC is the International Electrotechnical Commission).

  • EC -6: DIN VDE -: Erection of low-voltage installations Part 6: Verification.

Flooring resistance can be measured in different ways: between its top and bottom surface (R1), between two points on the flooring surface (R3 or Rp-p) or between one point on the surface and the ground (R2 or Rg). Rg is generally the most useful value during the specification and verification after the installation.

It is also important to determine whether ground means the protective earth of the power distribution system or an arbitrary zero reference point, such as the steel frame of a building. The test voltage must always be specified, as resistance varies with voltage.

Below is an outline of the tests laid out in each standard: 

EN :+A1: Resilient floor coverings determination of the electrical resistance

This standard describes test methods for measuring three different resistances:

  • Vertical resistance, R1, between a tripod electrode on the surface of the flooring and an electrode on its underside.

  • Resistance to earth, R2, between a tripod electrode on the surface and earth.

  • Surface resistance, R3, between two tripod electrodes, 100mm apart on the surface of the flooring.

Measurements should be taken when a force of over 30kg is applied to a tripod electrode. The test voltage varies, depending on the specified resistance.

IEC -5-1: Protection of electronic devices from electrostatic phenomena General requirements

This section of the IEC series of standards sets out how to create control programs for activities which involve equipment that could be susceptible to damage from ESD. It references other parts of the series (explained below) which it says are essential as part of a control program.

IEC -4-1: Standard test methods for specific applications Electrical resistance of floor coverings and installed floors

This part of the standard series sets out how to measure resistance to ground, Rg, and resistance from point to point, Rp-p. Rg is generally the most useful value during the specification and verification after the installation.

For Rg, the resistance in ohms is measured between a single electrode placed on the ground and an earthing point. Readings may be necessary at three different voltage settings. The number of measurements required is governed by the size of the floor.

Rp-p is measured between two electrodes at a prescribed spacing.

IEC -4-5: Standard test methods for specific applications - Methods for characterizing the electrostatic protection of footwear and flooring in combination with a person

This sets out test methods where the combined resistance of a person wearing special ESD footwear and the flooring must be assessed. A person wearing the shoes holds a handheld electrode with the negative lead connected to an earthing point or the earth.

The tests may need to be done at different voltages, depending on the resistance value being read. And they should be repeated with just one foot in contact with the floor.

This section also includes a measuring technique to determine the potential difference generated by a moving person walking forwards and backwards on the floor. This test is also called body voltage generation and it is used during product characterization. Results are measured in volts.

EC -6: DIN VDE -: Erection of low-voltage installations Part 6: Verification

This standard sets out how electrical installations should be tested initially and at intervals and includes the requirement to check the resistance of the flooring system. The standard describes the test method for flooring which is performed using a tripod electrode according to EN .

In conclusion

It is only possible to specify ESD and antistatic flooring if the appropriate test standards are understood. Descriptions of the electrical properties of an antistatic or ESD flooring system should be part of the specification process, while testing the electrical behaviour would be part of the verification after the installation.

 

 