FE1700 Zero Valent Iron Powder (ZVI Powder)

16, Dec. 2024

 

FE Zero Valent Iron Powder (ZVI Powder)

SECTION 1. IDENTIFICATION

Product Name: Zero Valent Iron Powder

With competitive price and timely delivery, NFJ sincerely hope to be your supplier and partner.

CAS #: -89-6

Relevant identified uses of the substance: Scientific research and development

Supplier details:

Stanford Advanced Materials

:

: (949) 407-

Address: Birtcher Dr., Lake Forest, CA U.S.A.

SECTION 2. HAZARDS IDENTIFICATION

Classification of the substance or mixture

Classification according to Regulation (EC) No /

GHS02 Flame

Flam. Sol. 2 H228 Flammable solid.

GHS07

Eye Irrit. 2A H319 Causes serious eye irritation.

STOT SE 3 H335 May cause respiratory irritation.

Classification according to Directive 67/548/EEC or Directive /45/EC

Xi; Irritant

R36/37: Irritating to eyes and respiratory system.

F; Highly flammable

R11: Highly flammable.

Information concerning particular hazards for human and environment:

N/A

Hazards not otherwise classified

No data available.

Label elements

Labelling according to Regulation (EC) No /

The substance is classified and labeled according to the CLP regulation.

Hazard pictograms

GHS02 GHS07

Signal word: Warning

Hazard statements

H228 Flammable solid.

H319 Causes serious eye irritation.

H335 May cause respiratory irritation.

Precautionary statements

P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking.

P261 Avoid breathing dust/fume/gas/mist/vapors/spray.

P280 Wear protective gloves/protective clothing/eye protection/face protection.

P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact

lenses, if present and easy to do. Continue rinsing.

P405 Store locked up.

P501 Dispose of contents/container in accordance with local/regional/national/international

regulations.

WHMIS classification

B4 - Flammable solid

D2B - Toxic material causing other toxic effects

Classification system

HMIS ratings (scale 0-4)

(Hazardous Materials Identification System)

HEALTH

FIRE

REACTIVITY

1

2

1

Health (acute effects) = 1

Flammability = 2

Physical Hazard = 1

Other hazards

Results of PBT and vPvB assessment:

PBT: N/A.

vPvB: N/A.

SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS

Substances

CAS No. / Substance Name:

-89-6 Iron

Identification number(s):

EC number: 231-096-4

SECTION 4. FIRST AID MEASURES

Description of first aid measures

If inhaled:

Supply fresh air. If not breathing, provide artificial respiration. Keep patient warm.Seek immediate medical advice.

In case of skin contact:

Immediately wash with soap and water; rinse thoroughly.

Seek immediate medical advice.

In case of eye contact:

Rinse opened eye for several minutes under running water. Consult a physician.

If swallowed:

Seek medical treatment.

Information for doctor

Most important symptoms and effects, both acute and delayed

No information available.

Indication of any immediate medical attention and special treatment needed

No information available.

SECTION 5. FIREFIGHTING MEASURES

Extinguishing media

Suitable extinguishing media

Special powder for metal fires. Do not use water.

For safety reasons unsuitable extinguishing media

Water

Special hazards arising from the substance or mixture

If this product is involved in a fire, the following can be released:

Advice for firefighters

Protective equipment:

Wear self-contained respirator.

Wear fully protective impervious suit.

SECTION 6. ACCIDENTAL RELEASE MEASURES

Personal precautions, protective equipment and emergency procedures

Wear protective equipment. Keep unprotected persons away.

Ensure adequate ventilation

Keep away from ignition sources

Environmental precautions:

Do not allow material to be released to the environment without official permits.

Do not allow product to reach sewage system or any water course.

Do not allow to penetrate the ground/soil.

Methods and material for containment and cleanup:

Keep away from ignition sources.

Ensure adequate ventilation.

Prevention of secondary hazards:

Keep away from ignition sources.

Reference to other sections

See Section 7 for information on safe handling

See Section 8 for information on personal protection equipment.

See Section 13 for disposal information.

SECTION 7. HANDLING AND STORAGE

Handling

Precautions for safe handling

Keep container tightly sealed.

Store in cool, dry place in tightly closed containers.

Ensure adequate ventilation.

Information about protection against explosions and fires:

Protect against electrostatic charges.

Conditions for safe storage, including any incompatibilities

Storage

Requirements to be met by storerooms and receptacles:

Store in a cool location.

Information about storage in one common storage facility:

Store away from oxidizing agents.

Further information about storage conditions:

Keep container tightly sealed.

Store in cool, dry conditions in well-sealed containers.

Specific end use(s)

No information available.

SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Additional information about design of technical systems:

Properly operating chemical fume hood designed for hazardous chemicals and having an average

face velocity of at least 100 feet per minute.

Control parameters

Components with limit values that require monitoring at the workplace:

-89-6 Iron (100.0%)

EV (Canada) Long-term value: 1* 5** mg/m³ as iron;*salts, water-soluble;**welding fume

TLV (Canada) Long-term value: 5 mg/m³

Additional information: No data

Exposure controls

Personal protective equipment

Follow typical general protective and industrial hygiene measures for handling chemicals.

Keep away from foodstuffs, beverages and feed.

Remove all soiled and contaminated clothing immediately.

Wash hands before breaks and at the end of work.

Avoid contact with the eyes.

Avoid contact with the eyes and skin.

Breathing equipment:

Use suitable respirator when high concentrations are present.

Protection of hands: Impervious gloves

Inspect gloves prior to use.

Suitability of gloves should be determined both by material and quality, the latter of which may vary by

manufacturer.

Penetration time of glove material (in minutes)

No data available.

Eye protection: Safety glasses

Body protection: Protective work clothing.

SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES

Information on basic physical and chemical properties

Appearance:

Form: Powder

Color: gray

Odor: No data available.

Odor threshold: No data available.

pH: N/A.

Melting point/range: °C ( °F)

Boiling point/range: °C ( °F)

Sublimation temperature / start: No data available.

Flammability (solid, gas):

Highly flammable.

Ignition temperature: No data available.

Decomposition temperature: No data available.

Auto igniting: No data available.

Danger of explosion: No data available.

Explosion limits:

For more information, please visit Nanometer ZVI for redox reactions.

Lower: No data available.

Upper: No data available.

Vapor pressure: N/A.

Density at 20 °C (68 °F): 7.87 g/cm³ (65.675 lbs/gal)

Bulk density at 20 °C (68 °F): kg/m³

Relative density

No data available.

Vapor density

N/A.

Evaporation rate

N/A.

Solubility in Water (H

2

O): No data available.

Partition coefficient (n-octanol/water): No data available.

Viscosity:

Dynamic: N/A.

Kinematic: N/A.

Other information

No information available.

SECTION 10. STABILITY AND REACTIVITY

Reactivity: No data available.

Chemical stability

Stable under recommended storage conditions.

Thermal decomposition / conditions to be avoided:

Decomposition will not occur if used and stored according to specifications.

Possibility of hazardous reactions

No dangerous reactions known

Conditions to avoid

No information available.

Incompatible materials: Oxidizing agents

Hazardous decomposition products: Iron oxides

SECTION 11. TOXICOLOGICAL INFORMATION

Information on toxicological effects

Acute toxicity:

The Registry of Toxic Effects of Chemical Substances (RTECS) contains acute toxicity data for this

substance.

LD/LC50 values that are relevant for classification:

Oral LD50 mg/kg (rat)

Skin irritation or corrosion: May cause irritation

Eye irritation or corrosion: Causes serious eye damage.

Sensitization: No sensitizing effects known.

Germ cell mutagenicity: N/A

Carcinogenicity:

No classification data on carcinogenic properties of this material is available from the EPA, IARC,

NTP, OSHA or ACGIH.

The Registry of Toxic Effects of Chemical Substances (RTECS) contains tumorigenic and/or

carcinogenic and/or neoplastic data for this substance.

Reproductive toxicity: N/A

Specific target organ system toxicity - repeated exposure: N/A

Specific target organ system toxicity - single exposure: May cause respiratory irritation.

Aspiration hazard: N/A

Subacute to chronic toxicity:

The Registry of Toxic Effects of Chemical Substances (RTECS) contains multiple dose toxicity data for

this substance.

Additional toxicological information:

To the best of our knowledge the acute and chronic toxicity of this substance is not fully known.

SECTION 12. ECOLOGICAL INFORMATION

Toxicity

Aquatic toxicity:

No information available.

Persistence and degradability:

No information available.

Bioaccumulative potential:

No information available.

Mobility in soil:

No information available.

Additional ecological information:

General notes:

Do not allow material to be released to the environment without official permits.

Avoid transfer into the environment.

Results of PBT and vPvB assessment:

PBT: N/A.

vPvB: N/A.

Other adverse effects

No further relevant information available

SECTION 13. DISPOSAL CONSIDERATIONS

Waste treatment methods

Recommendation:

Consult state, local or national regulations to ensure proper disposal.

Uncleaned packagings:

Recommendation:

Disposal must be made according to official regulations.

SECTION 14. TRANSPORT INFORMATION

UN-Number

DOT, IMDG, IATA

UN

UN proper shipping name

DOT

Metal powders, flammable, n.o.s. (Iron )

IMDG, IATA

METAL POWDER, FLAMMABLE, N.O.S. (Iron )

Transport hazard class(es)

DOT

Class

4.1 Flammable solids, self-reactive substances and solid desensitised explosives.

Label

4.1

Class

4.1 (F3) Flammable solids, self-reactive substances and solid desensitised explosives

Label

4.1

IMDG, IATA

Class

4.1 Flammable solids, self-reactive substances and solid desensitised explosives.

Label

4.1

Packing group

DOT, IMDG, IATA

III

Environmental hazards:

N/A.

Special precautions for user

Warning: Flammable solids, self-reactive substances and solid desensitised explosives

Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code

N/A.

Transport/Additional information:

DOT

Marine Pollutant (DOT):

No

UN "Model Regulation":

UN, Metal powders, flammable, n.o.s. (Iron ), 4.1, III

SECTION 15. REGULATORY INFORMATION

Safety, health and environmental regulations/legislation specific for the substance or mixture

National regulations

All components of this product are listed in the U.S. Environmental Protection Agency Toxic

Substances Control Act Chemical substance Inventory.

All components of this product are listed on the Canadian Domestic Substances List (DSL).

SARA Section 313 (specific toxic chemical listings)

Substance is not listed.

California Proposition 65

Prop 65 - Chemicals known to cause cancer

Substance is not listed.

Prop 65 - Developmental toxicity

Substance is not listed.

Prop 65 - Developmental toxicity, female

Substance is not listed.

Prop 65 - Developmental toxicity, male

Substance is not listed.

Information about limitation of use:

For use only by technically qualified individuals.

Other regulations, limitations and prohibitive regulations

Substance of Very High Concern (SVHC) according to the REACH Regulations (EC) No. /.

Substance is not listed.

The conditions of restrictions according to Article 67 and Annex XVII of the Regulation (EC) No

/ (REACH) for the manufacturing, placing on the market and use must be observed.

Substance is not listed.

Annex XIV of the REACH Regulations (requiring Authorisation for use)

Substance is not listed.

REACH - Pre-registered substances

Substance is listed.

Chemical safety assessment:

A Chemical Safety Assessment has not been carried out.

SECTION 16. OTHER INFORMATION

Safety Data Sheet according to Regulation (EC) No. / (REACH). The above information is

believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The

information in this document is based on the present state of our knowledge and is applicable to the

product with regard to appropriate safety precautions. It does not represent any guarantee of the

properties of the product.

Application and development of zero-valent iron (ZVI) for ...

Principles

To enhance the efficiency of ZVI, nanoscale zero-valent iron (nZVI) was invented. Nanomaterials are defined as those materials whose key physical characteristics are defined by the nano-objects they contain (Kharisov et al. ). nZVI ranges from 10 to 100 nm (Li et al. ).

For laboratory-sized applications, the generally used method for nZVI manufacturing is the boron hydride reduction of ferrous salts (Crane and Scott ; Chekli et al. ; Sun et al. ). But for the production of a bigger amount, there are many different methods, e.g. chemical vapour deposition, pulsed laser ablation, sputtering gas aggregates, thermal decomposition, thermal reduction of oxide compounds and many more (Crane and Scott ).

An enormous advantage of nZVI is that it can be directly injected into the contaminated groundwater plumes or source zones without the need for ex situ methods or intensive digging and without clogging of pores (Cundy et al. ). nZVI is generally injected into the subsurface as a slurry or as an emulsion with a hydrophobic fluid, this should prevent the agglomeration of particles and enhance the reactivity and mobility (Cundy et al. ). Due to this method, the injection wells can be installed at almost any location and depth with minimal disturbance to the area above (Chekli et al. ; Hashim et al. ). Even areas that are unreachable with most other conventional technologies, including those underneath surface barriers, where only in situ methods are feasible, can be treated (He et al. ). The injected nanoparticles should be virtually immobile once the external injection pressure is released and they should pose no adverse environmental effect (Zhao et al. ).

Applications

The application of nZVI for environmental remediation (groundwater, wastewater, soil) has extensively been studied in the last 15'20 years (Calderon and Fullana ; Guan et al. ; Vanzetto and Thomé ; Li et al. ). Contaminated sites often contain a complex and varied mixture of contaminants from heavy metals to organic pollutants (Cundy et al. ; Li et al. ). Because of such complex contaminations, it is highly important that nZVI can perform fast and concurrent removal of different heavy metal ions (Li et al. ). There are already some field applications of nZVI, most sites are located in the USA, and only a small number of pilot studies have been conducted in Europe (Karn et al. ).

The zero-valent iron nanoparticles age rapidly in water due to interaction with dissolved compounds and corrosion, and this results in structural and chemical changes of the nZVI depending on the environment (Calderon and Fullana ). Calderon and Fullana () studied the ageing of nZVI with Zn, Cd, Ni, Cu and Cr as typical contaminants found in groundwater and wastewater. The removal efficiency of all elements in the first 3 h was '''99.9%, but only Cr showed no remobilization after an extended period, because it was the only element that was incorporated into the nZVI core. Cd and Ni showed the maximum remobilization with 65% and 27% after 21 days. Crane et al. () and Dickinson and Scott () showed similar results in the removal of uranium with nZVI, with a partial release of 20% of the retained uranium after one week and 60% after 3 weeks. At a Portuguese metal contamination site, Gonçalves () applied nZVI and observed that at first the concentration was reduced to 60% below initial concentration, but within 4 weeks the elevation of the contaminants was close to the initial values. In contrast, Gonçalves () attributed this effect to groundwater recharge and not to some kind of ageing effect of the nZVI. Calderon and Fullana () also proved that mainly the pH changes of the solution were responsible for the release of metal ions into the water; this also shows that some metals are only in equilibrium with the shell of the nZVI and not entrapped in the core.

The different factors (e.g. mobility, reactivity, tendency to aggregate) determining the feasibility of nZVI depend heavily on properties such as particle size, surface charge, surface chemistry and bulk composition (Chekli et al. ). The particle size of nZVI has a major influence on the reactivity and mobility of the nanoparticles (Hassellöv et al. ; Christian et al. ). In comparison with highly dispersed nanoparticles, highly aggregated particles have reduced available reactive surface sites (Nurmi et al. ). The composition of the oxide shell and the metallic iron content of the implemented nZVI has a substantial influence on the efficacy of the nZVI treatment (Grieger et al. ; O'Carroll et al. ). The composition of the outer shell is dependent on the method of synthesis and the nanoparticle environment (Nurmi et al. ).

Factors affecting the reactivity of nZVI are diverse and include surface area, nZVI stabilizer, pH, soil organic matter, soil type, temperature, dissolved oxygen, soil moisture and aged soil (Jiang et al. ; Xue et al. ; Zhao et al. ). The reactivity of some pollutants with ZVI depends also on the age of the pollutants in the soil, and El-Temsah and Joner () reported that the degradation of dichlorodipenyltrichloroethane (DDT) in spiked soil was 50%, whereas the removal efficiency in aged DDT polluted soil was only at 24%. This could be due to desorption, solubilization and dissolution of DDT in the soil. A weakly acidic soil increases the dechlorination rate of polychlorinated biphenyls (Wang et al. ). The pH also has an impact on the reactive lifetime due to corrosion effects and the reactivity towards the target contaminant (Zhao et al. ; Dickinson and Scott ). The pH is also a key parameter for metal transfer in soil, e.g. the As availability is lower in acidic soils than in calcareous ones (Xue et al. ; Gil-Díaz et al. ). The soil organic matter has many different contrary effects; for example, the organic matter can coat the nZVI and form a barrier for electron transfer which inhibits the reactivity towards the contaminants, but the same effect leads to a prolonged reactive lifetime of the nZVI (Zhang et al. ). Zhao et al. () also concluded that the soil organic matter can form complexes with heavy metals and thus change the adsorption and immobilization of metals. Stabilizers for nZVI lead to a better soil mobility due to less particle agglomeration (Jiang et al. ). It was also proved that the efficiency of nZVI in soil is related to the leachability and bioavailability of contaminants, higher leachability and bioavailability are beneficial, but those factors depend heavily on the soil type (Xue et al. ; Chen et al. ). For example, a higher sand content in comparison with a high clay content was shown to be preferable for a high removal rate (Chen et al. ).

Advantages

Even though the chemistry behind nZVI and ZVI or mZVI (macroscale ZVI) is much the same, nZVI, due to the large surface area, is more reactive than ZVI, shows higher reductive efficiency and is also able to migrate in the underground to some extent, which allows active remediation not only of the plume but also of the source of contaminants (Mueller et al. ). nZVI holds even some more advantages, as summarized by Guan et al. (): (1) it can successfully remove some aqueous contaminant species due to its large surface area that mZVI cannot remove, (2) it degrades some contaminants more rapidly and (3) it avoids the formation of some undesirable by-products due to a more complete degradation.

nZVI has been proved to be a feasible method to transform a wide range of contaminants to low toxicity or inert compounds (Crane and Scott ; Xue et al. ), including all kinds of metals and metalloids like chromium (Cr), cobalt (Co), copper (Cu), lead (Pb), nickel (Ni), zinc (Zn), cadmium (Cd), arsenic (As), selenium (Se) and actinides such as uranium (U) and plutonium (Pu) (e.g. Table 4). Also some organic compounds like chlorinated pesticides, organophosphates, nitroamines, nitroaromatics, p-chlorphenol and some inorganic anions such as nitrate could be removed (e.g. Table 4), whereas nitrate was reduced to ammonia (Sohn et al. ).

Table 4 Compilation of different studies regarding the application of nZVI

Full size table

Disadvantages and optimization

Even though nZVI seems to be already more feasible than ZVI for environmental remediation, the enhancement of nZVI has been thoroughly studied (Jiang et al. ; Zhao et al. ), especially since bare nZVI has a limited soil mobility and deliverability (Crane and Scott ). Thus, in order to enhance the feasibility of nZVI and decrease the toxic effects on soil micro-organisms and the entire biosphere, chemical and physical methods were developed to improve the performance (Jiang et al. ). Physical enhanced technologies include dispersion and acoustic cavitation of nZVI using ultrasonic technology for nanoparticle, UV light or electric forces (Jiang et al. ). The nanoparticles can also be combined with another metal, bound onto a support or the surface modified (Xue et al. ). For example, to improve the reduction reactions nZVI has been coated with a catalyst, such as platinum (Pt), nickel (Ni), gold (Ag), palladium (Pd) or copper (Cu), and those products are then called bimetallic nanoparticles (Guan et al. ). nZVI could also be deployed in a combination with biotechnology, such as phytoremediation or microbial remediation, which would be an environmental-friendly and cost-effective remediation strategy (Jiang et al. ).

Stabilized nZVI has three significant advantages: (1) the stabilizers prevent the aggregation through electrostatic and/or steric repulsion, (2) they may offer a greater reactivity and (3) due to different physical and chemical properties the dispersibility, chemical reactivity, reactive longevity and toxicity of nZVI may be better controlled (Zhao et al. ; Xue et al. ). The coating of stabilizers onto nanoparticles may also passivate the reactive particle surface from reaction with the media (e.g. H2O and dissolved oxygen) (Zhao et al. ).

Zhao et al. () categorized possible stabilizers for nZVIs into the following five groups: (I) surfactants, (II) synthetic or natural macromolecules or polyelectrolytes, (III) viscosity modifiers, (IV) oil emulsifiers and (V) micro-scale solid supports or coatings. Stabilized nZVI shows promising results for the degradation of redox-active organics and reductive immobilization of many metals, metalloids and radionuclides (Zhao et al. ). Cao et al. () tested the feasibility of nZVI in combination with organic acids. The removal efficiency of heavy metals was improved when nZVI was combined with organic acids, such as citric acid, tartaric acid and oxalic acids. The removal efficiency increased with increasing concentration of nZVI and solid-to-liquid ratio and decreased with increasing solution pH. Gopal et al. () enhanced nZVI-Cu particles with bentonite support to overcome colloidal attraction and enhance total carbon removal. Li et al. () anchored nZVI on Zn-MOF-74, thus significantly enhancing the removal of U(VI).

nZVI is extremely challenging to characterize and analyse due to their high reactivity, but it is crucial for the understanding and reproducibility of each project to report appropriate and detailed characterization of the nZVI (Chekli et al. ). There is also a definite lack of appropriate analytical methods for on-site detection and measurement of nZVI (Chekli et al. ). Natural environments and contaminations sites can vary widely from studies conducted in a closed system in the laboratory, and this can lead to a drastic overestimation of nZVI performance (Calderon and Fullana ; Guan et al. ; Li et al. ; Ye et al. ).

One of the biggest disadvantages of nZVI is its tendency for agglomeration during migration probably due to weak surface charges, and this leads to a reduced surface area and mobility as well as a deterioration of reactivity and an overall reduced efficiency (Chekli et al. ; Sun et al. ; Ye et al. ; Guan et al. ). However, sometimes lower reactivity is preferred, especially when treating slow moving groundwater, as in this case high reactivity requires more frequent injection of nZVI, which also leads to undesired cost and maintenance issues. Another one is the high reactivity of dry, bare nZVI with oxygen in the atmosphere; this leads to a passivation of the surface with a thin oxide layer (Chekli et al. ; Sun et al. ; Ye et al. ; Guan et al. ). This exothermic reaction entails also a logistic and safety problem, and there are two main approaches to make nZVI transportable: firstly as a slurry and secondly to deliberately passivate the surface (Ribas et al. ). To mitigate the decrease in reactivity due to the passivation, Ribas et al. () invented an activation process, which degrades the oxide shell and enhances the electron transfer and increases the specific surface area of the nZVI.

Cundy et al. () reasoned that nZVI could not be employed in a permeable reactive barrier (PRB) system or a similar flow-through application due to their lack of durability and extremely high pressure drops. Seven years later, Zhang et al. () confirmed the feasibility of nZVI as the reactive medium in PRB on the basis of in situ remediation of uranium-contaminated red soils, even though there are still major influences (poor stability, mobility of nZVI and tendency for aggregation), limiting the reduction reactivity in the soil. This technology may not be suited for sites with a slow contaminant desorption rate, as a result of the relative short reactive lifetime (Zhao et al. ).

nZVI that was injected during the in situ treatment of a contaminated site was left in the underground (Crane and Scott ). The contaminants that were not destroyed by chemical reactions were trapped in an immobile state and were not extracted from the groundwater or soil (Calderon and Fullana ). If those metastable systems gradually reverse towards a pre-injection state, a significant remobilization can occur (Calderon and Fullana ; Crane et al. ; Crane and Scott ). nZVI also has the disadvantage of relatively high costs in contrast to macro-ZVI and granular iron (Table 5).

Table 5 Short overview of the costs of nZVI, ZVI and granular iron

Full size table

Many toxicological concerns derive from the beforehand desired properties of nZVI like the small size, high reactivity and mobility (Cundy et al. ). Most research works regarding the toxicity of nZVI have shown a negative impact on many micro-organisms, especially for gram-negative bacteria (Fajardo et al. ). According to Vanzetto and Thomé (), USA and China are the leading nations in research regarding the toxicological impact of nZVI. The cytotoxicity includes disruption to the cell membrane integrity, interference with respiration and oxidative damage of DNA or enzymatic proteins by the generation of reactive oxygen species (ROS) (Vanzetto and Thomé ; Xie et al. ; Xue et al. ). The general trend was that with increasing nZVI concentration the toxicity to bacterial cells also increases (Fajardo et al. ), even though some researchers found the inverse trend that high concentrations were less toxic (Fajardo et al. ). Some surface stabilizers like CMC (carboxymethyl cellulose) are able to decrease the damages to cell membrane integrity, whereas the modification with other metals increases the toxicity (Xue et al. ). The treatments of aquifer sediments with nZVI showed a long-term adverse impact on the micro-organism (Vanzetto and Thomé ). It was found that fungal cells have a higher tolerance for nZVI than bacteria cells (Xue et al. ). It was observed that the organic matter decreases the toxicity of nZVI (Navarro et al. ; Pawlett et al. ). Aged nZVI also had a reduced toxic effect, probably due to the formation of the iron oxide layer (El-Temsah and Joner ). Baragaño et al. () found the best results of removal rate of 89.5% at a dose of 2% nZVI (also tested 0.5%, 2%, 5% and 10%), with no negative effects on soil parameter and the soil phytotoxicity was also reduced. Dong et al. () summarized the effect of nZVI on three types of functional anaerobic bacteria in the remediation of contaminated groundwater. The study proved that nZVI could create suitable environmental conditions for cell growth, but that it was highly dependent on the species and dosage of nZVI.

If you want to learn more, please visit our website Polymeric friction and sealing materials.