Economical Column Design (Rule of Thumb)
3
thread507- Forum Search FAQs Links MVPsForum
Search
FAQs
Links
MVPs
(Structural)
(OP)
21 Oct 20 08:56Hi
I am new to columns or any vertical member design. I only know some of the basic theories.
Lets say I am free to choose whatever column size I want. May I know based on your experience, where is the most economical point (NEd, MEd) on the column-interaction diagram? Reinforcement ratio? 2%? And why?
Thanks, and Best Regards,
2
Trenno(Structural)
21 Oct 20 09:06Columns with minimum moment:
For Stocky columns 0.5*f'c at Le/r=20
For Slender columns 0.4*f'c at Le/r=35 ; 0.3*f'c at Le/r=45 ; 0.2*f'c at Le/r=60 and 0.05*fc at Le/r=100
Effective Length (Le) = Length * K-fixity factor. Conservative to assume k=1.0.
Radius of Gyration (r) = sqrt (Imin/A) or 0.3*min dimension for rectangular and 0.25*radius for circular.
(Structural)
21 Oct 20 12:59Like so many simple questions, the answer is complicated.
Given that reinforcement is expensive, choose a column size where the reinforcement needed is the bare minimum. Of course, there are code-required reinforcement and detailing minimums for ductility. The higher your seismicity, the more additional requirements there are
If possible, you want to make your column sizes as uniform as reasonably possible and vary the reinforcement where additional capacity is needed. Consult with local contractors as to which nominal sizes have standard formwork available.
Round columns are probably the most "efficient" for axial-load-dominated columns, but round formwork and spiral ties can be expensive.
One of the biggest gripes from the field is the congestion of the rebar where the girders connect into the columns. A few big bars in the girders and a few big bars in the columns can make rebar placement a nightmare. Or an impossibility. If you sketch the bars to scale you get a sense of whether or not your joint is constructible.
High strength concrete gives you, well, high strength columns. Know what materials are available in your region and specify them appropriately. You can spec different strength concrete for columns than the floor framing, but you better have excellent quality control to make it happen.
I worked on a hospital where the bulk of the columns were 20"x20" with (4) #9 bars. Exactly 1% and just 4 bars in the columns. It doesn't get more efficient than that.
(Structural)
21 Oct 20 17:20Trenno, that's a good explanation thanks man
(Structural)
21 Oct 20 17:36Quote:
I worked on a hospital where the bulk of the columns were 20"x20" with (4) #9 bars. Exactly 1% and just 4 bars in the columns. It doesn't get more efficient than that.
Just be aware most codes would have limits on the spacing of reinforcement on each side of the member and on the minimum number of longitudinal bars (usually more than 4). The rules are there to ensure good ductility and confinement. So make sure you follow all your local rules. Start typically by satisfying all the detailing provisions for your chosen column size and then increase bar size until you satisfy the strength requirements. If you predominantly have flexure in one direction, then varying the bar size first on the compression amd tension faces is obviously more efficient. Having different sized bars in different locations is relatively easy. But too many changes makes the chances of getting something wrong on site more of a prospect.One thing I've noted in the past is the amount of reinforcing going into the stirrups can be significantly more than you expect, but people concentrate on longitudinal reinforcement only when optimising. Sometimes for heavier columns your confinement reinforcement may be greater than 50% of the total reinforcement by weight. So don't forget to review that.
(Structural)
21 Oct 20 23:45Quote (Columns with minimum moment:)
Trenno:Great rule of thumb... been around for 50 years that I know of...
Rather than think climate change and the corona virus as science, think of it as the wrath of God. Feel any better?
-Dik
(Structural)
(OP)
22 Oct 20 05:41Hi Thanks Everyone,Trenno, Thanks That will surely useful for me later on.I am also curious that in the interaction diagram below is point C considered better / more efficient than points B & D due to this enhanced moment capacity?
(Structural)
22 Oct 20 05:45Chasing point C (which I believe is what you meant) will usually create false economy if column formwork sizes change and layout becomes more complicated.
----
just call me Lo.
(Structural)
22 Oct 20 06:16I believe forum member IDS produced the following chart (AS).Notice how slenderness effects kick in at Le/r = 20.
(Structural)
22 Oct 20 15:18Quote (OP)
I am also curious that in the interaction diagram below is point C considered better / more efficient than points B & D due to this enhanced moment capacity?
Much depends on how you're defining "better" and "more efficient".1) [C,D,E] are better than [A,B] from an engineering and safety perspective because values below the balanced point [C] will produced a more ductile failure mode not governed by rebar yielding rather than concrete compression failure. This may be of enhanced importance in situations of high seismic demand.2) [E] is basically a beam rather than a column and in many instances, I would consider that economical and spatially inefficient.3) In the lower stories of a high-rise building where moments become negligible relative to axial demand in gravity columns, I feel that even being as low as [C] on the graph represents economical and spatial inefficiency.Like others, I feel that formwork and congestion concerns dominate concrete column economy.As far as I'm concerned, circular columns are for architects. The circular bar pattern always seems to cause congestion issues for me. If I'm not overly concerned about confinement issues around the outside of a circular column, I'll usually just stuff a square cage in there.
(Structural)
22 Oct 20 16:20Does this mean that the axial capacity of a minimum moment column is 0,5*fc'*column_area for Le/r=20?Quote (Trenno)
Columns with minimum moment: For Stocky columns 0.5*f'c at Le/r=20...
Does this mean that the axial capacity of a minimum moment column is 0,5*fc'*column_area for Le/r=20?
(Structural)
22 Oct 20 16:49I've got a related question that would fit in well here although it will be kind of an ugly ask.
I have a printout of an amazing concrete concrete design spreadsheet prepared by another firm which I cannot share. It does pretty much an entire high-rise building with detailing, shear stud reinforcing etc. I would not feel comfortable calling them up and asking about the inner working of their intellectual property.
The most interesting part of the spreadsheet, to me at least, is that it seems to deal with preliminary design very handily. There's a bit in the documentation where they basically say "If Mb < 2.5 MPa, don't sweat the reinforcing, something will work. This confirms that the column size will be adequate and the reinforcing can be sorted out later". If you think about the work flow on a typical high-rise concrete building, this is a hugely powerful tool if it's legit. Nobody cares what the rebar is early on but being able to dial in sizes for your architect with minimal effort is a big win. Trouble is: I don't know anything about this 2.5MPa method. The spreadsheet setup suggests that Mb = Moment / Section modulus. That makes sense to me but why 2.5MPa should be a reasonable limit is not apparent to me.
Anybody know anything about this method? Maybe it comes from some ancient text book or ACI paper I don't know of? Part of what may make this difficult to parse out is that the 2.5MPa is in metric units and may well be a modified version of something else that would have been expressed in imperial units that would probably be easier to identify.
(Structural)
22 Oct 20 17:10You want to keep the same column size for 3 or 4 floors, and not change each floor, or keep the same size.
Link to Zolo
Rather than think climate change and the corona virus as science, think of it as the wrath of God. Feel any better?
-Dik
(Structural)
22 Oct 20 17:20I'd say it just results in an infinitesimally small moment.
For example for a 600 x 600 column the 2.5MPa limit calcs out to a moment of 90kNm. Minimum steel would probably net you several times this, and if subject to any seismic loads or gravity loads with any sort of reasonable beam span 90kNm would be quickly exceeded.
I'm not aware of anything formally noting this type of thing. But it sounds more like a best practice/experience limit they have found?
(Structural)
22 Oct 20 17:21I feel that the 2.5MPa makes a lot of sense when you actually think about it and compare it to Trenno's guidance. That's likely going to be pretty close to 0.1fc' for moderately slender columns and if you end up with a highly slender column, you go up to 50 or 60 MPa and then you're at the 0.05fc' intent.
(Structural)
22 Oct 20 17:25Quote (Agent666)
But it sounds more like a best practice/experience limit they have found?
Thanks Agent, you may well be right about that.
(Structural)
22 Oct 20 17:28For rectangular columns:Quote (KootK)
If Mb < 2.5 MPa, don't sweat the reinforcing
For rectangular columns:M/(bh/6) = 2,5 MPaM/(bh) = 2,5/6Since non-dimensional moment mi = M/(bhfc)M/(bh) = mi*fcmi*fc = 5/12If concrete of 30 MPa is used (around 4 ksi) and partial factor of safety is 1,5 (design strength is 20 MPa):mi < 0,02Isn't this very low (for higher concrete strengths, this moment is even lower)? Looking at an interaction (Moment - axial force) diagram, this seems like an area with less than minimum reinforcement.Or did I miscalculate something?
(Structural)
22 Oct 20 17:28Quote (jayrod12)
...and if you end up with a highly slender column...
Thanks for your contribution. The documentation does, in fact, start off by saying that most of the columns in their typical building will wind up being slender. You know the drill in the residential towers: 300x, 250x, 200x. The dreaded slender wallumn that will persist until explicitly prohibited.
(Structural)
22 Oct 20 17:30Quote (hardbutmild)
Isn't this very low (for higher concrete strengths, this moment is even lower)?
It is. To be honest, the setup is opaque enough to me that I may well be missing a 12 x multiplication somewhere or something. So I'd like to not get too caught up on the particular values. I'm really just interested to know if there are any good sizing methods out there that do account for significant moments and slenderness. This is the first that I've seen. And it may well be that it's just hugely conservative. Based on the work to which this setup would typically be applied, the moments would generally be quite small relative to the axial demand as they would be mostly just slab moments modelled with very liberal estimates of column stiffness.
[Post Deleted](Structural)
22 Oct 20 20:43Maybe the 2.5 MPa is an approximation to flexural tensile strength and therefore minimum bending strength. 2.5 MPa = 0.6 * sqrt( psi).
(Structural)
23 Oct 20 06:23That was my first thought too Steve, but I don't think your conversion works.
----
just call me Lo.
(Structural)
23 Oct 20 06:530.6 *sqrt(f'c) is for metric units, so you convert psi to 17.2MPa before running the calc.
(Structural)
23 Oct 20 09:45Ah, right you are!
----
just call me Lo.
(Structural)
23 Oct 20 13:13I looked at taking:Pu = PhiPn,max = 0.85*0.65*((0.85*F'c*(Ag-Ast))+(Fy*Ast))substitute Ag = b*h and Ast = (1/100)*b*hDetermine a M,min as (0.6+0.03*h)*PuThen the max ratio of Secondary to First order moments is 1.4, so M = M,min/1.4divide both sides by s = b*h*h / 6From here I plugged in Fy = 60,000 psi, F'c = [,,,] and h = [12,18,24,36]This results in PSI values so I divided by 145 to get Mpa. The 24 and 36 h at the lower F'c comes in near 2.5Steveh49 likely has it, but I found some fun new math software so took it for a spin.My Personal Open Source Structural Applications:Open Source Structural GitHub Group:
Please let us know here why this post is inappropriate. Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework.
Thank you for helping keep Eng-Tips Forums free from inappropriate posts.
The Eng-Tips staff will check this out and take appropriate action.
Click Here to join Eng-Tips and talk with other members! Already a Member? Login
News
Summary
Whether its better for a company to rent or purchase formwork items and systems depends on the kind of project under development and the time it will take to complete. Either way, the supplies needed must be of high quality and durability to ensure the timely, accident-free completion of the work. This means that your formwork provider should be a professional who has the requisite capacity to meet a projects needs, as well as the technical know-how to customize options and deliver.
Therefore, it is advisable that you watch out for suppliers with a limited product range. Often they will cut prices on standard-forming jobs but will have to quit when it comes to the more challenging part where know-how is needed. By contrast, a more experienced provider with an extensive range can supply custom-made forms.
Ultimately, it pays to only buy or rent from established companies with extensive experience. Ensure that the company you select offers professional and on-time design, with the technical capabilities to provide support to your engineering teams. You should be wary of formwork companies that offer discounted rates as they tend to use counterfeit products. Moreover, they do not maintain equipment to the best standards. This fails to provide the safety and peace of mind that you need to ensure quality work on your project.
In this report, we highlight what you should look out for when choosing a formwork provider for your construction needs.
INDEX
ADDITIONAL FORMWORK RECOMMENDATIONS
5 THINGS YOU NEED TO KNOW WHEN CHOOSING YOUR FORMWORK PROVIDER
When it comes to choosing your formwork provider, you cannot afford to make your decision too quickly. There are specific things that you need to look for when purchasing or hiring formwork systems. The correct formwork can make a construction project a success, whereas using the wrong systems can literally bring down a building.
Formwork makes up about 1.2% of the total costs of a buildings structural work. But you would be incorrect in thinking the role it plays is simple and insignificant. In fact, choosing good quality from a reliable provider is one of the most important decisions youll make for your project.
Here are five things you need to look for when selecting a formwork provider for your next construction project.
It goes without saying that safety and quality are of the utmost importance with any type of formwork or scaffolding. Thats why you should look for a provider who is committed to the following:
The simple truth is that quality formwork systems do not have to be exorbitantly expensive. In designing and building formwork, you should aim for maximum economy, which you can do by focusing on the following points:
Look for someone with proven formwork experience across a variety of sectors. The following factors will help you determine if a possible provider has the experience you need for your project.
Formwork systems should be quick and easy to erect and dismantle and have the following attributes:
Make sure your formwork supplier has sufficient product and capacity by examining these elements.
ADDITIONAL FORMWORK RECOMMENDATIONS
It goes without saying that you need to source the right kind of materials for specific construction requirements. A professional formwork provider knows these requirements.
Although many formworks have certain commonalities that can be used in most construction situations, in modern times, the design specificity and related mechanical requirements are more demanding on the bearing capacity of concrete buildings, and their shapes. Therefore, you must be careful to choose an informed provider who has the latest equipment at their disposal.
To guide buyers through the challenge of sourcing technical formwork, we list some products here to help you familiarize yourself with available options.
You may consider asking your provider for more details when it comes to supporting your construction needs.
For more information on modular formwork and scaffolding, what would work best for your project, and how you can get the support you need to ensure your construction is safe and efficient, contact the experts at SSF by clicking here.
INTELLIGENT WORK FORUMS
FOR ENGINEERING PROFESSIONALS
FIRST NAME
*
LAST NAME
*
*
MESSAGE
*
ADDITIONAL DETAILS
Thanks. We have received your request and will respond promptly.
Log In
Are you an
Engineering professional?
Join Eng-Tips Forums!
*Eng-Tips's functionality depends on members receiving . By joining you are opting in to receive .
Promoting, selling, recruiting, coursework and thesis posting is forbidden.
Eng-Tips Posting Policies
Economical Column Design (Rule of Thumb)
3
thread507- Forum Search FAQs Links MVPsForum
Search
FAQs
Links
MVPs
(Structural)
(OP)
21 Oct 20 08:56Hi
I am new to columns or any vertical member design. I only know some of the basic theories.
Lets say I am free to choose whatever column size I want. May I know based on your experience, where is the most economical point (NEd, MEd) on the column-interaction diagram? Reinforcement ratio? 2%? And why?
Thanks, and Best Regards,
2
Trenno(Structural)
21 Oct 20 09:06Columns with minimum moment:
For Stocky columns 0.5*f'c at Le/r=20
For Slender columns 0.4*f'c at Le/r=35 ; 0.3*f'c at Le/r=45 ; 0.2*f'c at Le/r=60 and 0.05*fc at Le/r=100
Effective Length (Le) = Length * K-fixity factor. Conservative to assume k=1.0.
Radius of Gyration (r) = sqrt (Imin/A) or 0.3*min dimension for rectangular and 0.25*radius for circular.
(Structural)
21 Oct 20 12:59Like so many simple questions, the answer is complicated.
Given that reinforcement is expensive, choose a column size where the reinforcement needed is the bare minimum. Of course, there are code-required reinforcement and detailing minimums for ductility. The higher your seismicity, the more additional requirements there are
If possible, you want to make your column sizes as uniform as reasonably possible and vary the reinforcement where additional capacity is needed. Consult with local contractors as to which nominal sizes have standard formwork available.
Round columns are probably the most "efficient" for axial-load-dominated columns, but round formwork and spiral ties can be expensive.
One of the biggest gripes from the field is the congestion of the rebar where the girders connect into the columns. A few big bars in the girders and a few big bars in the columns can make rebar placement a nightmare. Or an impossibility. If you sketch the bars to scale you get a sense of whether or not your joint is constructible.
High strength concrete gives you, well, high strength columns. Know what materials are available in your region and specify them appropriately. You can spec different strength concrete for columns than the floor framing, but you better have excellent quality control to make it happen.
I worked on a hospital where the bulk of the columns were 20"x20" with (4) #9 bars. Exactly 1% and just 4 bars in the columns. It doesn't get more efficient than that.
(Structural)
21 Oct 20 17:20Trenno, that's a good explanation thanks man
(Structural)
21 Oct 20 17:36Quote:
I worked on a hospital where the bulk of the columns were 20"x20" with (4) #9 bars. Exactly 1% and just 4 bars in the columns. It doesn't get more efficient than that.
Just be aware most codes would have limits on the spacing of reinforcement on each side of the member and on the minimum number of longitudinal bars (usually more than 4). The rules are there to ensure good ductility and confinement. So make sure you follow all your local rules. Start typically by satisfying all the detailing provisions for your chosen column size and then increase bar size until you satisfy the strength requirements. If you predominantly have flexure in one direction, then varying the bar size first on the compression amd tension faces is obviously more efficient. Having different sized bars in different locations is relatively easy. But too many changes makes the chances of getting something wrong on site more of a prospect.One thing I've noted in the past is the amount of reinforcing going into the stirrups can be significantly more than you expect, but people concentrate on longitudinal reinforcement only when optimising. Sometimes for heavier columns your confinement reinforcement may be greater than 50% of the total reinforcement by weight. So don't forget to review that.
(Structural)
21 Oct 20 23:45Quote (Columns with minimum moment:)
Trenno:Great rule of thumb... been around for 50 years that I know of...
Rather than think climate change and the corona virus as science, think of it as the wrath of God. Feel any better?
-Dik
(Structural)
(OP)
22 Oct 20 05:41Hi Thanks Everyone,Trenno, Thanks That will surely useful for me later on.I am also curious that in the interaction diagram below is point C considered better / more efficient than points B & D due to this enhanced moment capacity?
(Structural)
22 Oct 20 05:45Chasing point C (which I believe is what you meant) will usually create false economy if column formworkcolumn formwork sizes change and layout becomes more complicated.
----
just call me Lo.
(Structural)
22 Oct 20 06:16I believe forum member IDS produced the following chart (AS).Notice how slenderness effects kick in at Le/r = 20.
(Structural)
22 Oct 20 15:18Quote (OP)
I am also curious that in the interaction diagram below is point C considered better / more efficient than points B & D due to this enhanced moment capacity?
Much depends on how you're defining "better" and "more efficient".1) [C,D,E] are better than [A,B] from an engineering and safety perspective because values below the balanced point [C] will produced a more ductile failure mode not governed by rebar yielding rather than concrete compression failure. This may be of enhanced importance in situations of high seismic demand.2) [E] is basically a beam rather than a column and in many instances, I would consider that economical and spatially inefficient.3) In the lower stories of a high-rise building where moments become negligible relative to axial demand in gravity columns, I feel that even being as low as [C] on the graph represents economical and spatial inefficiency.Like others, I feel that formwork and congestion concerns dominate concrete column economy.As far as I'm concerned, circular columns are for architects. The circular bar pattern always seems to cause congestion issues for me. If I'm not overly concerned about confinement issues around the outside of a circular column, I'll usually just stuff a square cage in there.
(Structural)
22 Oct 20 16:20Does this mean that the axial capacity of a minimum moment column is 0,5*fc'*column_area for Le/r=20?Quote (Trenno)
Columns with minimum moment: For Stocky columns 0.5*f'c at Le/r=20...
Does this mean that the axial capacity of a minimum moment column is 0,5*fc'*column_area for Le/r=20?
(Structural)
22 Oct 20 16:49I've got a related question that would fit in well here although it will be kind of an ugly ask.
I have a printout of an amazing concrete concrete design spreadsheet prepared by another firm which I cannot share. It does pretty much an entire high-rise building with detailing, shear stud reinforcing etc. I would not feel comfortable calling them up and asking about the inner working of their intellectual property.
The most interesting part of the spreadsheet, to me at least, is that it seems to deal with preliminary design very handily. There's a bit in the documentation where they basically say "If Mb < 2.5 MPa, don't sweat the reinforcing, something will work. This confirms that the column size will be adequate and the reinforcing can be sorted out later". If you think about the work flow on a typical high-rise concrete building, this is a hugely powerful tool if it's legit. Nobody cares what the rebar is early on but being able to dial in sizes for your architect with minimal effort is a big win. Trouble is: I don't know anything about this 2.5MPa method. The spreadsheet setup suggests that Mb = Moment / Section modulus. That makes sense to me but why 2.5MPa should be a reasonable limit is not apparent to me.
Anybody know anything about this method? Maybe it comes from some ancient text book or ACI paper I don't know of? Part of what may make this difficult to parse out is that the 2.5MPa is in metric units and may well be a modified version of something else that would have been expressed in imperial units that would probably be easier to identify.
(Structural)
22 Oct 20 17:10You want to keep the same column size for 3 or 4 floors, and not change each floor, or keep the same size.
Rather than think climate change and the corona virus as science, think of it as the wrath of God. Feel any better?
-Dik
(Structural)
22 Oct 20 17:20I'd say it just results in an infinitesimally small moment.
For example for a 600 x 600 column the 2.5MPa limit calcs out to a moment of 90kNm. Minimum steel would probably net you several times this, and if subject to any seismic loads or gravity loads with any sort of reasonable beam span 90kNm would be quickly exceeded.
I'm not aware of anything formally noting this type of thing. But it sounds more like a best practice/experience limit they have found?
(Structural)
22 Oct 20 17:21I feel that the 2.5MPa makes a lot of sense when you actually think about it and compare it to Trenno's guidance. That's likely going to be pretty close to 0.1fc' for moderately slender columns and if you end up with a highly slender column, you go up to 50 or 60 MPa and then you're at the 0.05fc' intent.
(Structural)
22 Oct 20 17:25Quote (Agent666)
But it sounds more like a best practice/experience limit they have found?
Thanks Agent, you may well be right about that.
(Structural)
22 Oct 20 17:28For rectangular columns:Quote (KootK)
If Mb < 2.5 MPa, don't sweat the reinforcing
For rectangular columns:M/(bh/6) = 2,5 MPaM/(bh) = 2,5/6Since non-dimensional moment mi = M/(bhfc)M/(bh) = mi*fcmi*fc = 5/12If concrete of 30 MPa is used (around 4 ksi) and partial factor of safety is 1,5 (design strength is 20 MPa):mi < 0,02Isn't this very low (for higher concrete strengths, this moment is even lower)? Looking at an interaction (Moment - axial force) diagram, this seems like an area with less than minimum reinforcement.Or did I miscalculate something?
(Structural)
22 Oct 20 17:28Quote (jayrod12)
...and if you end up with a highly slender column...
Thanks for your contribution. The documentation does, in fact, start off by saying that most of the columns in their typical building will wind up being slender. You know the drill in the residential towers: 300x, 250x, 200x. The dreaded slender wallumn that will persist until explicitly prohibited.
(Structural)
22 Oct 20 17:30Quote (hardbutmild)
Isn't this very low (for higher concrete strengths, this moment is even lower)?
It is. To be honest, the setup is opaque enough to me that I may well be missing a 12 x multiplication somewhere or something. So I'd like to not get too caught up on the particular values. I'm really just interested to know if there are any good sizing methods out there that do account for significant moments and slenderness. This is the first that I've seen. And it may well be that it's just hugely conservative. Based on the work to which this setup would typically be applied, the moments would generally be quite small relative to the axial demand as they would be mostly just slab moments modelled with very liberal estimates of column stiffness.
[Post Deleted](Structural)
22 Oct 20 20:43Maybe the 2.5 MPa is an approximation to flexural tensile strength and therefore minimum bending strength. 2.5 MPa = 0.6 * sqrt( psi).
(Structural)
23 Oct 20 06:23That was my first thought too Steve, but I don't think your conversion works.
----
just call me Lo.
(Structural)
23 Oct 20 06:530.6 *sqrt(f'c) is for metric units, so you convert psi to 17.2MPa before running the calc.
(Structural)
23 Oct 20 09:45Ah, right you are!
----
just call me Lo.
(Structural)
23 Oct 20 13:13I looked at taking:Pu = PhiPn,max = 0.85*0.65*((0.85*F'c*(Ag-Ast))+(Fy*Ast))substitute Ag = b*h and Ast = (1/100)*b*hDetermine a M,min as (0.6+0.03*h)*PuThen the max ratio of Secondary to First order moments is 1.4, so M = M,min/1.4divide both sides by s = b*h*h / 6From here I plugged in Fy = 60,000 psi, F'c = [,,,] and h = [12,18,24,36]This results in PSI values so I divided by 145 to get Mpa. The 24 and 36 h at the lower F'c comes in near 2.5Steveh49 likely has it, but I found some fun new math software so took it for a spin.My Personal Open Source Structural Applications:Open Source Structural GitHub Group:
Please let us know here why this post is inappropriate. Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework.
Thank you for helping keep Eng-Tips Forums free from inappropriate posts.
The Eng-Tips staff will check this out and take appropriate action.
Click Here to join Eng-Tips and talk with other members! Already a Member? Login
News
Summary
Whether its better for a company to rent or purchase formwork items and systems depends on the kind of project under development and the time it will take to complete. Either way, the supplies needed must be of high quality and durability to ensure the timely, accident-free completion of the work. This means that your formwork provider should be a professional who has the requisite capacity to meet a projects needs, as well as the technical know-how to customize options and deliver.
Therefore, it is advisable that you watch out for suppliers with a limited product range. Often they will cut prices on standard-forming jobs but will have to quit when it comes to the more challenging part where know-how is needed. By contrast, a more experienced provider with an extensive range can supply custom-made forms.
Ultimately, it pays to only buy or rent from established companies with extensive experience. Ensure that the company you select offers professional and on-time design, with the technical capabilities to provide support to your engineering teams. You should be wary of formwork companies that offer discounted rates as they tend to use counterfeit products. Moreover, they do not maintain equipment to the best standards. This fails to provide the safety and peace of mind that you need to ensure quality work on your project.
In this report, we highlight what you should look out for when choosing a formwork provider for your construction needs.
INDEX
ADDITIONAL FORMWORK RECOMMENDATIONS
5 THINGS YOU NEED TO KNOW WHEN CHOOSING YOUR FORMWORK PROVIDER
When it comes to choosing your formwork provider, you cannot afford to make your decision too quickly. There are specific things that you need to look for when purchasing or hiring formwork systems. The correct formwork can make a construction project a success, whereas using the wrong systems can literally bring down a building.
Formwork makes up about 1.2% of the total costs of a buildings structural work. But you would be incorrect in thinking the role it plays is simple and insignificant. In fact, choosing good quality from a reliable provider is one of the most important decisions youll make for your project.
Here are five things you need to look for when selecting a formwork provider for your next construction project.
It goes without saying that safety and quality are of the utmost importance with any type of formwork or scaffolding. Thats why you should look for a provider who is committed to the following:
The simple truth is that quality formwork systems do not have to be exorbitantly expensive. In designing and building formwork, you should aim for maximum economy, which you can do by focusing on the following points:
Look for someone with proven formwork experience across a variety of sectors. The following factors will help you determine if a possible provider has the experience you need for your project.
Formwork systems should be quick and easy to erect and dismantle and have the following attributes:
Make sure your formwork supplier has sufficient product and capacity by examining these elements.
ADDITIONAL FORMWORK RECOMMENDATIONS
It goes without saying that you need to source the right kind of materials for specific construction requirements. A professional formwork provider knows these requirements.
Although many formworks have certain commonalities that can be used in most construction situations, in modern times, the design specificity and related mechanical requirements are more demanding on the bearing capacity of concrete buildings, and their shapes. Therefore, you must be careful to choose an informed provider who has the latest equipment at their disposal.
To guide buyers through the challenge of sourcing technical formwork, we list some products here to help you familiarize yourself with available options.
You may consider asking your provider for more details when it comes to supporting your construction needs.
For more information on modular formwork and scaffolding, what would work best for your project, and how you can get the support you need to ensure your construction is safe and efficient, contact the experts at SSF by clicking here.