5 Benefits of FRP Tanks

04, Aug. 2025

 

5 Benefits of FRP Tanks

5 Benefits of FRP Tanks

FRP, or fiberglass reinforced plastic, tanks have significant advantages over other commercial materials. Over the years of development, various materials have been used in the construction of water tanks for industrial purposes. Many integrated systems are constructed of non-reinforced concrete or polyethylene and steel, but they don’t necessarily provide the same benefits of fiberglass. So, what are the advantages of fiberglass reinforced plastic?

Yongchang supply professional and honest service.

1. Corrosion Resistance

The prime reason for using fiberglass reinforced plastics (FRP) is because of their inherent corrosion resistance. Suppose you need a product that will be exposed to freshwater, saltwater, sanitary water, or even the high salt content in the air near the ocean. In that case, corrosive resistant FRP is your material. Paired with the right resin, FRP can hold up in the most corrosive environments.

2. High Strength to Weight Ratio

FRP is not only durable but lightweight as well. On average, FRP weighs around 5.5 times less than a similar steel piece and is 75% lighter than a comparable aluminum piece. This lightweight attribute of FRP products can allow for a much easier installation. (Easier installations mean much lower installation costs!)

3. Non-Conductive/EMI and RFI Transparency

Electromagnetic interference (EMI) or radio-frequency interference (RFI) is crucial to take into consideration when you have equipment or instrumentation that depends on accurate readings. FRP material is transparent to electromagnetic and radio frequency interference. Additionally, FRP is non-conductive, so it works well as an electrical insulator

4. Economy

A considerable advantage of FRP is its lower cost. FRP is almost one-sixth of the price of stainless or carbon steel. In many cases, FRP may offer both a satisfactory solution to corrosion problems and the lowest cost among material options. Due to its excellent corrosion resistance, FRP can save more than 70% on maintenance costs.

5. Flexibility

Fiberglass can be made into many different shapes and sizes relatively easily as compared to metal. It is best for many applications because you can do things with it that cannot be done economically with other materials. You can mold almost any configuration or piece of equipment. It is even possible to use FRP to line existing structures.

FRP tanks are among the best when it comes to a water storage system. It is second-to-none for economy, customization, and strength when compared to other offerings in the industry. At American Sealants Inc. (ASI), we provide FRP and FRP tanks for turn-key, plug-and-play aquariums, water-retaining systems, touch tanks, large displays, and small displays: we do it all! Ready for unparalleled excellence? Call us for a quote!

Fibre-reinforced plastic tanks and vessels

FRP (Fibreglass Reinforced Plastics, also known as GRP, or Glass Reinforced Plastics) is a modern composite material of construction for chemical plant, pulp and paper mill, and food and pharmaceutical equipment like tanks and vessels. Chemical equipment that range in size from less than a metre to 20 metres [1] are fabricated using FRP as material of construction.

FRP Chemical Equipments are manufactured mainly by Hand Lay-up and filament winding processes. BS still remains a key standard for this class of items.

Dual Laminate

[

edit

]

Due to the corrosion resistant nature of FRP, the tank can be made entirely from the composite, or a second liner can be used. In either case, the inner liner is made using different material properties than the structural portion (Hence the name dual (meaning two) and laminate (a word commonly used for a layer of a composite material))

The liner, if made of FRP is usually resin rich and utilizes a different type of glass, called "C-Glass", while the structural portion uses "E-Glass". The thermoplastic liner is usually 2.3 mm thick (100 mils). This thermoplastic liner is not considered to contribute mechanical strength. The FRP liner is usually cured before winding or lay-up continues, by using either a BPO/DMA system, or using an MEKP catalyst with cobalt in the resin.

If the liner is not made of FRP, there are multiple choices for a thermoplastic liner. The engineer will need to design the tank based on the chemical corrosion requirement of the equipment. PP, PVC, PTFE, ECTFE, ETFE, FEP, CPVC, PVDF are used as common thermoplastic liners.

Due to FRP's weakness to buckling, but immense strength against tensile forces and its resistance to corrosion, a hydrostatic tank is a logical application for the composite. The tank is designed to withstand the hydrostatic forces required by orienting the fibres in the tangential direction. This increases the hoop strength, making the tanks anisotropically stronger than steel (pound per pound).

FRP which is constructed over the liner provides the structural strength requirements to withstand design conditions such as internal pressure or vacuum, hydrostatic loads, seismic loads (including fluid sloshing), wind loads, regeneration hydrostatic loads, and even snow loads.

Applications

[

edit

]

FRP tanks and vessels designed as per BS are widely used in the chemical industry in the following sectors: chlor-alkali manufacturers, fertilizer, wood pulp and paper, metal extraction, refining, electroplating, brine, vinegar, food processing, and in air pollution control equipment, especially at municipal waste water treatment plants and water treatment plants.

Types

[

edit

]

FRP tanks and process vessels are used in various commercial and industrial applications, including chemical, water & wastewater, food & beverage, mining & metals, power, energy, and high-purity applications.

Scrubbers

[

edit

]

FRP Scrubbers are used for scrubbing fluids. In air pollution control technology, scrubbers come in three varieties, Dry Media, Wet Media, and Biological.

Dry Media

[

edit

]

Dry media typically involved a dry, solid media (such as activated carbon) suspended in the middle of the vessel on a system of beam supports and grating. The media controls the concentration of a pollutant in the incoming gas via adsorption and absorption.

These vessels have several design constraints. They must be designed for

Unloading and Reloading the media

Corrosive effects of the fluid to be treated

Internal and External Pressure

Environmental Loads

Support Loads for the grating and support system

Lifting and Installing the Vessel

Regenerating the media inside the vessel

Internal Stack supports for a dual bed construction

Redundancy for preventative maintenance

Demisting to remove liquids that degrade the dry media

Condensate removal, to remove any liquid that condenses inside the vessel

Wet media

[

edit

]

Wet media scrubbers typically douse the polluted fluid in a scrubbing solution. These vessels must be designed to more stringent criteria. The design constraints for wet media scrubbers typically include:

The corrosive effects of the polluted fluid and the scrubbing solution.

The high pressures and loading of a spray system

Aerodynamics of the internal media to ensure that there is no bypass

Internal Support systems

Reservoir of scrubbing fluid for recirculation.

Internal and External Pressure

Environmental Loads

Lifting and Installing the vessel

Plumbing of the scrubbing fluid to the vessel

Draining to remove vessel sump fluids

In the case of a decarbonator, used in reverse osmosis systems to limit the concentration of gases in the water, the air is the scrubbing fluid and the sprayed liquid is the polluted stream. As the water is sprayed out of the scrubber, the air strips the aqueous gasses out of the water, to be treated in another vessel.

Biological

[

edit

]

Biological scrubbers are structurally identical to the wet media scrubbers, but vary in their design. The vessel is designed to be larger, so the air moves slower through the vessel. The media is designed to encourage biological growth, and the water that sprays through the vessel is filled with nutrients to encourage bacteria to grow. In such scrubbers, the bacteria scrub the pollutant. Also, instead of a single, large support system (typically 10 feet depth of media for chemical scrubbers), there are multiple stages of media support, that can change the design requirements of the vessel. (See biofilter for similar technology that is usually performed outside of an FRP vessel.)

Tanks

[

edit

]

A typical storage tank made of FRP has an inlet, an outlet, a vent, an access port, a drain, and an overflow nozzle. However, there are other features that can be included in the tank. Ladders on the outside allow for easy access to the roof for loading. The vessel must be designed to withstand the load of someone standing on these ladders, and even withstand a person standing on the roof. Sloped bottoms allow for easier draining. Level gauges allow someone to accurately read the liquid level in the tank. The vessel must be resistant to the corrosive nature of the fluid it contains. Typically, these vessels have a secondary containment structure, in case the vessel bursts.

Size

[

edit

]

The size of FRP Vessels is rarely limited by manufacturing technology, but rather by economics. Tanks smaller than 7,500 liters (2,000 gallons) are easily manufactured out of cheaper materials, such as HDPE or PVC. Tanks larger than four meters are generally limited by shipping constraints, and the economics suggest a concrete or steel tank fabricated at the tank's location.

For chemical storage and air pollution control, the choice is to make multiple tanks of smaller diameters. For example, one of the largest odor control projects in California, the Orange County Sanitation District will utilize 24[2] vessels total to treat 188,300 cfm (86,200 L/s) of odorous air, with a design of up to 50 ppm of hydrogen sulfide.[3] For an equivalent single vessel to perform as well as the 13 headworks trickling filters, the single vessel would have to be over 36 feet in diameter.[4] This would be impractical due to the high shipping requirements, internal supports, spray nozzles and other internals. Plus this single vessel would not incorporate redundancy for preventive maintenance.

Limitations

[

For more FRP Tank Manufacturersinformation, please contact us. We will provide professional answers.

edit

]

Typical FRP vessels and constructs limits are almost entirely based on the application parameters and resins used. The thermoplastic resin will suffer from creep at elevated temperatures and ultimately fail. However, new chemistry has produced resins that claim to be able to achieve even higher temperatures, which expand this field immensely. The typical maximum is 200 degrees Celsius.

Fiberglass vessels and constructs are also susceptible to degradation upon long-term exposure to sunlight. This deterioration is brought about by chemical changes which occur as a result of exposure to the ultraviolet (UV) portion of light. Degradation results in the fiberglass tanks and constructs, opening pores in the surface allowing styrene to wick out of the vessel or construct's walls, causing them to become embrittled, reducing the impact resistance and potential elongation properties of the part. Degradation from UV light can be effectively inhibited by the addition of exterior gelcoats and sealants, which protect the fiberglass construct through removing UV access to the product's surface thus deflecting UV energy.

The UV life of a part is dependent upon UV additive level and type as well as part thickness and design, pigment type, level and effectiveness of dispersion, processing conditions and the geographic location where the molded part is used (see Figure 3). It is important when comparing resin UV performance to ensure that the testing has been done on a consistent basis. In Figure 1, accelerated weathering data is presented. Generally, 2,000 hours corresponds to 1 year in Florida and 1,400 hours to 1 year in Southern Canada. Often terms like “UV-8” are used. UV-8 means the material can withstand 8,000 hours in a Xenon Ci-65 weatherometer. UV-2 or UV-4 would mean 2,000 or 4,000 hours respectively. Hence, UV-8 corresponds to approximately 4 years of continuous outdoor exposure in Florida. It is important to understand which weatherometer, i.e. Carbon Arc or Xenon, was used, as well as the details of how the weatherometer was run. ASTM D- is the recognized standard. Testing can be performed using actual outdoor weathering exposure, such as Florida and Arizona, to confirm this data. Note Figure 1 uses the industry standard criteria of when the sample has reached less than 50% of its original break elongation to determine the end of the test. In most cases useful life of the part extends beyond this point. All samples in Figure 1 are nonpigmented as supplied by Exxon Chemical. The UV performance test data can be found on our data sheets for each specific grade. Light Stability Characteristics Ultraviolet (UV) Stabilization Plastics are attacked and deteriorate when exposed to direct sunlight. When plastic tanks absorb the sun's ultraviolet light, the UV energy excites the polymers’chains, causing them to break. The effects are discoloration, embrittlement and eventual cracking. Elevated temperatures and oxygen tend to accelerate the deterioration. Tanks listed as suitable for outdoor service are protected from UV attack by: coloring or pigmenting and/or adding internal stabilizers which preferentially absorb or dissipate the UV energy. Shading tanks from the sun will also prevent deterioration. Tanks must be free to expand or contract, avoid excessive tension on the tank. For assistance in selecting the appropriate tank for a specific application, see the Tank Resin Selector Guides with reputable resin manufacturers. Resources being published by [5] siting additional references to AVENGENERAL ISOLINES OF GLOBAL RADIATION AND THERE EFFECTS ON POLYMERS Years = 70 x UV Rating (Your Location's Isoline) (from Figure 3) Example: Natural Part, Molded Properly, Using UV-8 Additive Package For Use in Florida i.e.Florida= 140 Kcal/cm@2/yr. (from Figure 3) Thus Years “Expected”= 70/140 x 8 = 4 Years (until 50% of original break elongation properties left.

Think of protecting your fiberglass investments from UV, much the same way you would protect your children with sun screen; gelcoats are sunscreens for your tanks, vessels and other fiberglass constructs.

Design standards

[

edit

]

Fiberglass Tanks fall under regulation of several groups.

Bs-87 is the British Standards Standard for FRP Tanks and Vessels superseded by EN .

EN

ASME RTP-1 (Reinforced Thermoset Plastic Corrosion Resistant Equipment) is the standard for FRP tanks and vessels held within the United States under 15 psig and located partially or fully above ground.

 Typical design parameters and specifications will require either compliance with ASME RTP-1 or accreditation from ASME.

ASTM which is only a product specification, governs the filament winding process for tanks. It is not a design standard.

SS245: Singapore Standard for Sectional GRP Water Storage Tanks.

Bs

[

edit

]

It is to avoid the uncertainty associated with specifying the thickness alone, that BS introduced the concept of "unit properties". It is property per unit width, per unit mass of reinforcement. For example, UNIT STRENGTH is defined as load in Newton per millimeter (of laminate width) for a layer consisting of 1 kg of glass per square meter. i.e. the unit is N/mm per Kg/m2 glass

ASME RTP-1

[

edit

]

In RTP-1 specifications, the primary concerns relate stress and strain, such as hoop stress, axial stress, and breaking stress to the physical properties of the material, such as Young's modulus (which may require an anisotropic analysis due to the filament winding process). These are related to the loads of the design, such as the internal pressure and strain.

BS EN

[

edit

]

This European standard replaces BS-87 which is marked now as Current, Obsolescent, Superseded.

This is the Singapore Standard for sectional GRP water tank, which is current.

Manufactures

[

edit

]

Mitsubishi Chemical Infratec

See also

[

edit

]

References

[

edit

]

^Newberry, Alfred L.; Putri, Gunung (-11-18). "World's largest FRP acid storage tanks". Reinforced Plastics. 49 (10): 26–29. doi:10./s-(05)-0.

^[1] Page 12, Plant 2 Headworks Facility

^Carollo Engineers , Orange County Sanitation District Plant No. 2 Headworks Replacement (Job No. P2-66) Specification D.1.3.A.3

^

13 ∗ π 4 ∗ 10 2 π 4 = 36.055 f t {\displaystyle {{\sqrt {13*{{\pi } \over {4}}*10^{2}}} \over {\pi \over 4}}=36.055ft}

Since area must be maintained to keep velocity reduced,

Chemical Storage: Polyethylene Vs. Fiberglass Reinforced Plastic Tanks


When considering storage solutions for chemicals, two options available are Polyethylene (poly) and fiberglass reinforced plastic (FRP). FRP tanks are available with numerous interior coatings and a structural layer comprised of chopped glass fiber and resin. Polyethylene storage tanks are either linear polyethylene or high-density crosslinked polyethylene.

High-density crosslinked polyethylene, or XLPE, is a thermoset resin that is specifically engineered for critical applications like chemical storage. Both poly and FRP chemical storage tanks are available in a variety of sizes.

Let’s explore the differences between these two storage tank options.

Fiberglass Reinforced Plastic Tanks

Contain seams - FRP storage tanks are not one-piece vessels, they contain seams. These are weak areas of the tank where leaks tend to occur.
 

Manufacturing challenges – FRP tanks are handcrafted in production, which is labor intensive and creates opportunities for human error.
 

Expense of materials – In addition to the challenge of controlling the quality of manufacture, FRP is expensive.  Resin rich corrosion barriers designed for common chemicals can increase these costs significantly.
 

Require increased maintenance - Since FRP storage tanks are subject to leaks at seams and corrosion of the tank develops over time, careful maintenance and inspection of the storage tank is needed, often requiring confined space entry.

Polyethylene Tanks

One piece construction - With a seamless one-piece molded construction, polyethylene storage tanks lack seams where leaks tend to develop.
 

Ease of manufacturing – Engineered production is controlled by an automated process, eliminating the risk of human error.
 

Resistance to corrosion - Polyethylene storage tanks, especially high-density crosslinked polyethylene tanks, are highly resistive to break down from exposure to a wide range of chemicals.  As a result, expensive coating applications are not required.
 

Less expensive - Due to lower cost of materials and expense of the manufacturing process, poly storage tanks are lower cost than FRP storage tanks.
 

Ease of maintenance - Without seams and different interior coatings, and given the corrosion resistance of poly storage tanks, maintenance and inspection to detect leaks is less of a chore.

Now you have the information required to compare fiberglass reinforced plastic versus polyethylene chemical storage tank options for your application. Check out our chemical storage tank buying guide for everything else you should consider when making your decision.

Need a customized solution to your chemical storage needs? Contact a Poly Processing storage tank specialist.

Benefits of Using Fiberglass Tanks Across Industries | Blog

Unmatched Durability and Long-Term Reliability

Fiberglass tanks offer exceptional structural integrity due to their high-strength glass fibers embedded in a durable resin matrix. This design makes fiberglass water tanks highly resistant to cracking, warping, and structural wear, unlike traditional metal and plastic tanks.

• Corrosion Resistance: Unlike metal, fiberglass doesn’t corrode, making it ideal for industries handling acids, salts, and other corrosive materials. This resistance significantly extends the lifespan of fiberglass tanks, even in harsh chemical environments.

• Temperature Tolerance: Fiberglass water storage tanks handle incredible temperature limits from sub-zero to 200°F, which means they are versatile enough to store everything from hot chemicals to chilled liquids without compromising structural integrity.

Choosing a fiberglass tank is an investment in a long-lasting, reliable solution that supports smooth operations with minimal interruptions.

Cost-Effectiveness and Low Maintenance Needs

Fiberglass tanks are not only durable but also offer substantial savings over time by reducing maintenance demands. They stand up to chemical reactions that can degrade other materials, which means fewer repairs and replacements.

• Minimal Maintenance: Due to their resistance to rust, corrosion, and temperature shifts, fiberglass tanks require fewer inspections, less frequent maintenance, and reduced downtime.

• Longevity Equals Savings: Investing in fiberglass storage tanks up front translates to fewer expenses down the line. This economical solution reduces both direct and indirect costs.

Fiberglass storage tanks for sale at Tank Depot come with warranties and certifications, giving you peace of mind and protecting your investment.

Agriculture: Reliable Storage for Chemicals and Water

Agricultural operations rely heavily on fiberglass water storage tanks to safely store fertilizers, pesticides, animal feed, and water for irrigation. The chemical resistance of fiberglass ensures safe containment of these substances without risk of contamination.

• Fertilizer and Pesticide Storage: With resistance to harsh chemicals, fiberglass tanks prevent harmful reactions that could jeopardize the tank’s integrity or contaminate stored materials.

• Rainwater Harvesting: Fiberglass tanks are lightweight and easy to install in challenging terrains, making them an ideal solution for farmers and agribusinesses needing dependable water storage.

Fiberglass tanks are revolutionizing grain storage in agriculture. Unlike their metal and plastic counterparts, these sleek silos act as impenetrable fortresses against moisture and pests, ensuring the longevity and quality of stored grains. This makes them the perfect solution for preserving harvests, whether for short-term needs or long-term reserves, especially in humid climates where grain spoilage is a constant threat.

Fiberglass tanks in agriculture offer peace of mind, especially for those handling volatile chemicals or storing critical resources like water.

Industrial Applications: Safe Containment for Corrosive Substances

Industries such as chemical manufacturing, oil and gas, and wastewater treatment often use fiberglass tanks to store aggressive chemicals that would corrode other materials. Fiberglass’s adaptability and resilience make it a top choice for handling substances like acids, alkalis, and salts.

• Chemical Storage: Fiberglass tanks can safely store volatile compounds, making them an essential asset for industrial facilities handling hazardous materials.

• Wastewater Treatment: With excellent biofouling resistance, FRP tanks ensure that water quality remains safe, preventing harmful chemical leaching into wastewater systems.

Using fiberglass tanks in these sectors not only enhances safety but also meets the rigorous standards required for hazardous substance storage.

Potable Water Storage: Safe for Drinking Water

For those wondering, “Are fiberglass water tanks safe for drinking water?”, the simple answer is YES. Fiberglass is an inert material, meaning it won’t interact with or contaminate the contents, making it suitable for potable water storage.

• Non-Toxic Material: Fiberglass doesn’t react with stored substances, ensuring that water remains safe for drinking and other applications.

• Resistant to Biofouling: The structure of fiberglass inhibits microbial growth, preserving water quality in potable water storage applications.

• Limited Space Solution: If space is a constraint, consider our customized underground fiberglass tanks. These below-ground fiberglass storage tanks won’t rust and can hold thousands of gallons.

Tank Depot’s fiberglass water tanks are a trusted solution for communities and companies needing secure, clean water storage.

Fire Suppression: Reliable Water Storage for Fire Protection Systems

Fiberglass storage tanks play a vital role in fire suppression applications by providing a durable, corrosion-resistant solution for storing large water volumes. Built to meet NFPA 22 standards, these tanks ensure that water is accessible and ready for use during emergencies.

The robust construction of fiberglass fire suppression tanks makes them ideal for industrial and commercial buildings, offering a dependable water supply to support fire safety protocols and keep facilities compliant with fire protection standards. For properties requiring reliable fire suppression systems, fiberglass storage tanks are a resilient and effective solution. 

Contact us to discuss your requirements of FRP Flange. Our experienced sales team can help you identify the options that best suit your needs.