Pipe support questions 3

30, Dec. 2024

 

Pipe support questions 3


The answer I gave about Pipe Stress Criteria is just a short form to answer the specific question.
When I teach Piping Designers and Stress Engineers (to work together) I have a longer answer. I also have an article published on pipingdesigners.con (

Here is my longer Pipe Stress Criteria answer:
Pipe Stress Criteria #1

The question:
What are the criteria for which lines need formal stress calculation?'

My answer:
You will get lots of opinions on this one. Here is what I use and teach.

1. 'The rule'
(from David Diehl, COADE)
a. If the line size (nominal pipe size) times (x) the temperature (degrees F) are below then the line "may" not need formal stress analysis.
Example 3'(x) 400 degrees (F) =

b. If the line size (nominal pipe size) times (x) the temperature (degrees F) are above then the line "may" need formal stress analysis.
Example 4" (x) 400 degrees (F) =

2. If the line (regardless of temperature) connects to a pump, a compressor or other alignment sensitive equipment then it should be submitted for formal stress analysis.

3. The "May" noted above relates to the application of good judgment when considering other factors such as metallurgy and the wall thicknesses above schedule 80.


Pipe Stress Criteria #2

The question:
What is the minimum recommended temperature or temperature range for which flexibility analysis should be done per ASME B31.3?

My answer:
I do not have a copy ASME B31.3 (Old or current ) so I can't cite any specifics therein. However I would be surprised if B31.3 would give a minimum temperature for the requirement of flexibility analysis. There are just too many variables.

Flexibility Analysis might come in a number of forms and should consider many situations.
Forms:
- Visual Review
- Informal Calculations
- Formal Analysis for excessive stress caused by common factors (Temperature induced expansion, Dead/Live Loads)
- Special Analysis (i.e.: Analog studies for reciprocating compressors, seismic studies, Sea-Force studies for Offshore Platforms)

Many engineering companies may set some minimum analysis criteria on a project by project basis but there is always the exception for even "That" project.
Exceptions may include:
- Very large diameter pipe
- Very heavy wall pipe
- Very thin wall pipe
- Exotic Alloy Pipe
- Attachment to strain sensitive equipment (Pumps, Glass lined vessels, etc.)
- Extremely low temperature (Cryogenic) systems
- Any pipe installed in Arctic locations
- All other lines below the stated minimum level on a job installed in a place like Oman or Kuwait

Even if the Code makes a recommendation on this subject each Piping Lead and the assigned Pipe Stress Engineer are responsible for the proper engineering and design of the project.

DSB123,The answer I gave about Pipe Stress Criteria is just a short form to answer the specific question.When I teach Piping Designers and Stress Engineers (to work together) I have a longer answer. I also have an article published on pipingdesigners.con () that deals with "What a Piping Designer needs to know about Pipe Stress."Here is my longer Pipe Stress Criteria answer:Pipe Stress Criteria #1The question:What are the criteria for which lines need formal stress calculation?'My answer:You will get lots of opinions on this one. Here is what I use and teach.1. 'The rule'(from David Diehl, COADE)a. If the line size (nominal pipe size) times (x) the temperature (degrees F) are below then the line "may" not need formal stress analysis.Example 3'(x) 400 degrees (F) = b. If the line size (nominal pipe size) times (x) the temperature (degrees F) are above then the line "may" need formal stress analysis.Example 4" (x) 400 degrees (F) = . If the line (regardless of temperature) connects to a pump, a compressor or other alignment sensitive equipment then it should be submitted for formal stress analysis.3. The "May" noted above relates to the application of good judgment when considering other factors such as metallurgy and the wall thicknesses above schedule 80.Pipe Stress Criteria #2The question:What is the minimum recommended temperature or temperature range for which flexibility analysis should be done per ASME B31.3?My answer:I do not have a copy ASME B31.3 (Old or current ) so I can't cite any specifics therein. However I would be surprised if B31.3 would give a minimum temperature for the requirement of flexibility analysis. There are just too many variables.Flexibility Analysis might come in a number of forms and should consider many situations.Forms:- Visual Review- Informal Calculations- Formal Analysis for excessive stress caused by common factors (Temperature induced expansion, Dead/Live Loads)- Special Analysis (i.e.: Analog studies for reciprocating compressors, seismic studies, Sea-Force studies for Offshore Platforms)Many engineering companies may set some minimum analysis criteria on a project by project basis but there is always the exception for even "That" project.Exceptions may include:- Very large diameter pipe- Very heavy wall pipe- Very thin wall pipe- Exotic Alloy Pipe- Attachment to strain sensitive equipment (Pumps, Glass lined vessels, etc.)- Extremely low temperature (Cryogenic) systems- Any pipe installed in Arctic locations- All other lines below the stated minimum level on a job installed in a place like Oman or KuwaitEven if the Code makes a recommendation on this subject each Piping Lead and the assigned Pipe Stress Engineer are responsible for the proper engineering and design of the project.

If you are looking for more details, kindly visit Zhiang.

If you are looking for more details, kindly visit Pipe Support.

Interview Questions Related To Pipes Supports

Piping supports are selected based on criteria including load, thermal loads, wind loads, vibration, and pipe size. Basic span lengths are 5.5m for 2" pipe, 9m for 6" pipe, 11.5m for 10" pipe, and 15m for 24" pipe. Anchors restrict movement, cross guides restrict perpendicular displacement, and guides restrict longitudinal movement. Piping to tank nozzles uses spring supports to accommodate displacement from thermal expansion or other loads. Flexible spring hangers include constant and variable spring types. Graphite pads in supports reduce friction. Anchors and slotted supports on heat exchangers consider maintenance access and piping growth. Material selection depends on factors like temperature,

For more information, please visit small high density cyrogenic pipe support with aluminum.