When designing or choosing a heat sink, thermal engineers try to optimize competing performance and cost requirements. In addition to maintaining optimal electronics component temperatures, the final heat sink design must also meet size, weight, durability, and cost targets. This page is organized to help engineers structure their thinking around the numerous variables considered when choosing or designing an air-cooled, non-pumped liquid heat sinking. Topics include:
You will get efficient and thoughtful service from Golden Jash.
Heat transfer occurs through conduction, convection, and radiation. Understanding the definition and relative importance each has on heat sink design helps engineers identify heat sink problem areas to keep the total temperature rise (Delta-T) of the thermal solution below the calculated thermal budget.
Conduction ' transfer of heat through a solid material due to the vibration and movement of atoms and molecules. In a heat sink, conduction occurs as heat moves from the electronic component through the thermal interface material(s), the heat sink's base, and the fins. In a heat sink application, conduction is critical for transferring heat from the heat source (e.g., electronic component) to the heat sink. It is crucial to ensure that heat is effectively spread throughout the heat sink before being dissipated to the surrounding environment.
Convection ' transfer of heat between a solid surface and a fluid (such as air or liquid) in motion. Heat sinks primarily rely on convection to dissipate heat into the surrounding environment. Convective heat transfer can be either natural (passive) or forced (active). For heat sink applications, convection is the tail that wags the dog in the sense that it's the primary exit point for heat yet determines how big the heat sink needs to be. The efficiency of convective heat transfer depends on factors such as airflow, the surface area of the fins, and fin geometry.
Radiation ' heat transfer through electromagnetic waves, typically in the infrared spectrum. Its contribution to heat transfer in heat sinks is generally much smaller compared to conduction and convection. Radiation becomes more important at higher temperatures, as the rate of heat transfer through radiation increases with the fourth power of the absolute temperature. However, in most electronic cooling applications, the operating temperatures are not high enough for radiation to have a significant impact on the overall heat transfer.
The portion of total heat sink thermal resistance caused by conduction is usually higher for applications directing airflow across the fin stack as fans or blowers aid in heat transfer away from the sinks and into the surrounding air. Conversely, those applications using natural convection generally have the bulk of their thermal resistance caused by convection.
Heat sink thermal performance is determined by adding each of the thermal resistances in the network and then multiplying that number (in oC/w) by the maximum power output of the heat source (TDP in watts) to get the total heat sink temperature rise.
The components of the thermal resistance network are shown on the right in the illustration below while the heat transfer mechanism associated with those resistances are shown on the left.
In a heat sink, there are layers of thermal resistance that affect the overall thermal performance. These include: the TIMs, bse of the heat sink, surface area of the fins, and available airflow across the fins. The thermal resistance for each of these components can be described as follows: Lower numbers indicate better performance.
The overall thermal resistance of the heat sink (R_total) can be estimated by adding the individual thermal resistance layers:
R_total = R-TIM + R-base conduction+R_base-fin + R_fin-air + R_air-rise
Engineers aim to minimize the total heat sink thermal resistance to ensure efficient heat dissipation and maintain the optimal operating temperature for the heat-generating components. By understanding the individual temperature rises at each stage of the thermal resistance chain, engineers can identify problem areas and quickly move toward relevant solutions. Visit our online heat sink performance calculator to show these values for a specific application.
The first two calculations likely to influence heat sink design requirements are thermal budget and maximum heat sink thermal resistance. Fortunately, they are easy to calculate from readily available information about the environment(s) in which the end product is designed to operate and about the heat source(s) used in that product.
Heat Sink Thermal Budget = Max Ambient Operating Temperature ' Max Tcase Temperature
Example: Tamb-max = 55 Tcase max =85 30°C thermal budget
Heat Sink Theta = Thermal Budget / IC Thermal Design Power
30°C/100w = 0.3°C/w
If it's an off-the-shelf IC, the datasheet provides both the Max T-case for lidded ICs. In the case of unlidded ICs, the datasheet will provide Max T-Junction from which the thermal resistance of the heat spreader and TIM will need to be added to the total thermal resistance network (delta-t calculation).
Material selection plays a vital role in heat sink design, as it directly affects both the thermal performance of the heat sink and the compatibility of mating surfaces (coatings/plating).
Heat sink thermal resistance and thermal conductivity are related concepts that describe different aspects of a heat sink's performance in dissipating heat. Here's how they are connected:
Thermal resistance: Thermal resistance is a measure of a heat sink's ability to dissipate heat from a heat-generating component to the surrounding environment. It is typically expressed in units of degrees Celsius per watt (°C/W). A lower thermal resistance indicates more effective heat dissipation.
Thermal conductivity: Thermal conductivity is a property of a material that quantifies its ability to conduct heat. It is typically expressed in units of watts per meter-kelvin (W/m·K). Materials with high thermal conductivity, such as copper and aluminum, are good at transferring heat and are commonly used in heat sink designs. The thermal conductivity of solid metals is constant, while heat pipe thermal conductivity varies depending on several factors.
The relationship between heat sink thermal resistance and thermal conductivity is that the thermal conductivity of the material used in a heat sink directly impacts the heat sink's thermal resistance. A heat sink made from a material with high thermal conductivity will generally have lower thermal resistance and provide better heat dissipation compared to one made from a material with lower thermal conductivity.
The table below lists the thermal conductivities of commonly used metals, two-phase devices, and TIMs used in heat sinks.
Material Type Thermal Conductivity (W/m·K) Aluminum Metal 205-230 Copper Metal 386-401 Heat Pipe / Vapor Chamber Two-Phase 2,000-25,000 (typical for electronics cooling) Thermal grease/paste Thermal Interface 0.5-6 Thermal pads Thermal Interface 1-10 Graphite Thermal Interface 200-500 Phase change materials Thermal Interface 0.5-4 Thermal adhesive Thermal Interface 0.5-3
Aluminum is the most widely used heat sink material for a variety of reasons:
When thermal resistance due to conduction is pushing the thermal solution over the thermal budget, engineers often turn to copper to help solve this issue.
To improve thermal performance through lower thermal resistance, engineers sometimes use copper in the base or base and fin sections of the heat sink. With a thermal conductivity of around 400 W/mK, copper can half the delta-t of thermal resistance due to conduction, but some notable disadvantages.
When both performance and weight or critical design features, engineers may incorporate heat pipes or vapor chambers into their heat sink designs.
Heat sink designs using heat pipes or vapor chambers can substantially decrease thermal resistance due to conduction, allowing engineers to reach lower thermal budget targets. The reason for the improvement is the higher thermal conductivity of two-phase devices. However, this figure which generally ranges between 2k-25k W/mK for electronics cooling applications is highly dependent on the distance heat travels to reach the fin section of the thermal solution; the longer the distance, the higher the thermal conductivity.
Using CFD software, Celsia modeled five competing heat sink designs where conduction thermal resistance was critical: solid aluminum base, solid copper base, aluminum base with embedded heat pipes, copper base with embedded heat pipes, and a vapor chamber base.
As seen in the table above, simply adding heat pipes to an aluminum base decreased thermal resistance by almost 50%, reducing the delta-t in the heat sinks base from 57.8 °C to to 33.2 °C with only a 2% increase in weight. However, there was a 50% cost increase but this is often necessary when thermal performance becomes more important.
In a second CFD analysis, five different kinds of heat pipe heat sinks were modeled. Here, the challenge was getting the heat a fin stack with fins parallel to the heat source.
This design exercise demonstrates how versatile different types of heat pipe designs can be at reducing the overall solution delta-t. For instance, the heat sink version using an all-aluminum base with attached U-shaped heat pipes had a delta-T of 53.9 °C compared to 37.8 °C delta-T for a U-shaped vapor chamber configuration making direct contact with the heat source.
Proper heat sink fin geometry is crucial for achieving efficient heat sink designs. Factors such as airflow, pressure drop, material properties, structural integrity, environmental exposure, and manufacturing methods all contribute to determining the ideal fin shape, thickness, spacing, and height for a given heat sink application.
Broadly speaking, heat sink fin shape falls into two categories: plate fins and pin fins. Plate fins are flat, parallel fin structures that extend from a heat sink base, providing a large surface area for heat transfer. Pin fins are cylindrical or elongated protrusions that extend from a heat sink base, offering improved air circulation.
In forced convection situations with high, directional airflow, plate fins often provide better performance due to their larger surface area and more streamlined shape. However, pin fins can offer superior performance in situations with multidirectional airflow as they allow for better air circulation around the fins.
The available space and weight limitations in the application can also influence the choice between plate fins and pin fins. Plate fin heat sinks tend to have a more compact profile, which may be advantageous in space-constrained applications. Pin fin heat sinks can offer better performance per unit volume in lower airflows and can be more easily adapted to irregular shapes.
Further, pin fins may be preferable in environments with dust or debris as they are less prone to clogging and easier to clean compared to plate fins.
Sub-categories of plate fins and pin fins include:
Plate Fins:
Pin Fins:
The choice of subcategories for plate fins and pin fins depends on various factors, such as the required heat transfer performance, the type of convection (natural or forced), and the specific application requirements along with tooling and production costs.
The thickness of fins in a heat sink is a complex consideration influenced by multiple factors. One significant aspect is the thermal conductivity of the material used in the heat sink. Higher thermal conductivity materials, like copper, enable better heat transfer along the fins, allowing for thinner fins or lower fin delta-Ts. In contrast, lower conductivity materials, usually aluminum, require thicker fins, but it also offers lower-cost manufacturing methods.
Apart from thermal conductivity, fin thickness also impacts the structural stability of the heat sink. Thicker fins offer better mechanical strength and can withstand deformation or damage better than thinner fins. However, thicker fins can increase the overall weight and size of the heat sink, which may be undesirable for certain applications.
The spacing between fins, also known as the fin gap, is a crucial key factor in determining the heat transfer efficiency of a heat sink. Proper spacing is essential for allowing adequate airflow with either natural or forced convection between the fins, which is essential for efficient heat dissipation. When fins are too closely spaced, airflow becomes impeded, and the increased pressure drop leads to reduced air flow and heat transfer efficiency. On the other hand, fins that are too widely spaced are inefficient and suboptimal. In addition to this, fin spacing affects the accumulation of dust and other particulates that can impede airflow and degrade the heat sink's performance over time. Increasing the fin spacing can help reduce the accumulation of dust and other particles and facilitate easier cleaning, thereby improving the heat sink's performance and reliability.
Fin height is another key factor in determining the heat transfer efficiency of a heat sink. Increasing the height of the fins can provide additional surface area, potentially leading to improved performance. However, taller fins may also add weight and cost to the heat sink, which can impact its overall effectiveness. In practice, taller fins can offer a larger face area for air to flow through, resulting in lower pressure drops and enhanced heat transfer performance. Therefore, the optimal fin height depends on the specific application requirements, operating conditions, and the trade-off between performance, weight, and cost. Ultimately, proper consideration of fin height can help optimize heat sink performance, but it should be balanced with other design factors, such as fin spacing and airflow velocity, to achieve the best results.
Unlike heat sink materials that can are chosen for a variety of reasons ' optimize performance, weight, durability, etc, fin geometry is primarily determined by performance criteria. Thin or closely spaced, or very tall fins cannot be used in natural convection applications. While engineers may be able to tweak these variables, they should do so only in small amounts. However, the cost component can be optimized, once the design is set, by choosing the manufacturing process that best matches performance, volume, and fin type goals. To see the effect of changes to fin geometry, visit our online heat sink performance calculator.
While types of heat sinks can be broken down into categories based on the amount of airflow and type of material, the manufacturing method used to produce the product affects cost. Each manufacturing technique has its advantages and limitations, and not all techniques are suitable for both straight fins (plate fins) and pin fins. Here is a summary of the mentioned manufacturing techniques and their suitability for straight fins and pin fins.
Extrusion is a common manufacturing technique for straight fins, where a metal (typically aluminum) is forced through a die with the desired fin shape. This method is cost-effective and can produce large, continuous lengths of heat sinks with uniform cross-sections. Aiming to emulate heat pin fin heat sinks produced by forging, extrusion manufacturers can cross-cut plate fin heat sinks.
Forging is a manufacturing process that employs high pressure and heat to transform a solid metal piece, such as aluminum or copper, into the desired shape for heat sinks. The forged heat sinks boast improved grain structure and orientation, resulting in enhanced thermal conductivity and mechanical properties. Although forging allows for the creation of complex geometries and intricate designs, it may have some limitations in design flexibility. Nevertheless, forged heat sinks offer a reliable and efficient solution for various thermal management applications, particularly when high strength, durability, and heat dissipation are crucial requirements.
Stamping is a process where metal sheets are cut and formed into the desired fin shapes using a stamping press. This method is typically used for straight fins made from thin metal sheets, such as aluminum or copper. Stamping is not suitable for pin fins due to their complex geometries and the limitations of the stamping process.
Skiving is a manufacturing technique that involves cutting and forming thin layers of metal from a solid block using a specialized tool. This process can produce straight fins with high aspect ratios and tight tolerances. Skiving is generally not suitable for pin fins due to the unique geometry and arrangement of the pins.
Bonded fins are created by attaching individual fins, either straight or pin, to a heat sink base using adhesives, brazing, or soldering. This technique allows for more complex fin arrangements and can be used for both straight and pin fins. However, bonded fins may have lower thermal performance compared to other manufacturing methods due to the added thermal resistance at the fin-base interface.
Zipper fins are a type of straight fin heat sink created by folding a thin metal sheet, typically aluminum or copper, into a continuous, interlocking fin structure. This method allows for high-density fin arrangements and is particularly suitable for forced convection applications. Zipper fins are not suitable for pin fins due to the nature of the folding process and the unique geometries of pin fins.
In conclusion, selecting the appropriate heat sink is a vital task for thermal engineers to ensure the optimal performance of electronic components while balancing size, weight, durability, and cost requirements. By understanding the essential aspects of heat transfer, thermal resistance, material selection, fin geometry and heat sink manufacturing methods engineers can make informed decisions when designing or choosing a heat sink to meet the specific needs of their application.
This article is about components used to cool electronics. For other uses, see Heat sink (disambiguation)
A fan-cooled heat sink on the processor of a personal computer. To the right is a smaller heat sink cooling another integrated circuit of the motherboard. Typical heatsink-fan combination found on a consumer laptop. The heatpipes which contain a working fluid make direct contact with the CPU and GPU, conducting heat away from the component and transferring it to the fin-stack mounted on the exhaust port of the cooling fan. The fin-stack acts as a fluid-to-fluid heat exchanger transferring thermal energy from the working fluid within the heatpipe(s) to ambient air at dead-state condition. A heat sink (aluminum) with its heat pipes (copper) and fan (black)A heat sink (also commonly spelled heatsink,[1]) is a passive heat exchanger that transfers the heat generated by an electronic or a mechanical device to a fluid medium, often air or a liquid coolant, where it is dissipated away from the device, thereby allowing regulation of the device's temperature. In computers, heat sinks are used to cool CPUs, GPUs, and some chipsets and RAM modules. Heat sinks are used with other high-power semiconductor devices such as power transistors and optoelectronics such as lasers and light-emitting diodes (LEDs), where the heat dissipation ability of the component itself is insufficient to moderate its temperature.
A heat sink is designed to maximize its surface area in contact with the cooling medium surrounding it, such as the air. Air velocity, choice of material, protrusion design and surface treatment are factors that affect the performance of a heat sink. Heat sink attachment methods and thermal interface materials also affect the die temperature of the integrated circuit. Thermal adhesive or thermal paste improve the heat sink's performance by filling air gaps between the heat sink and the heat spreader on the device. A heat sink is usually made out of a material with a high thermal conductivity, such as aluminium or copper.
[
edit
]
A heat sink transfers thermal energy from a higher-temperature device to a lower-temperature fluid medium. The fluid medium is frequently air, but can also be water, refrigerants or oil. If the fluid medium is water, the heat sink is frequently called a cold plate. In thermodynamics a heat sink is a heat reservoir that can absorb an arbitrary amount of heat without significantly changing temperature. Practical heat sinks for electronic devices must have a temperature higher than the surroundings to transfer heat by convection, radiation, and conduction. The power supplies of electronics are not absolutely efficient, so extra heat is produced that may be detrimental to the function of the device. As such, a heat sink is included in the design to disperse heat.
Fourier's law of heat conduction shows that when there is a temperature gradient in a body, heat will be transferred from the higher-temperature region to the lower-temperature region. The rate at which heat is transferred by conduction, q k {\displaystyle q_{k}} , is proportional to the product of the temperature gradient and the cross-sectional area through which heat is transferred. When it is simplified to a one-dimensional form in the x direction, it can be expressed as:
q k = ' k A d T d x . {\displaystyle q_{k}=-kA{\frac {dT}{dx}}.}
For a heat sink in a duct, where air flows through the duct, the heat-sink base will usually be hotter than the air flowing through the duct. Applying the conservation of energy, for steady-state conditions, and Newton's law of cooling to the temperature nodes shown in the diagram gives the following set of equations:
Q ˙ = m ˙ c p , in ( T air,out ' T air,in ) , {\displaystyle {\dot {Q}}={\dot {m}}c_{p,{\text{in}}}(T_{\text{air,out}}-T_{\text{air,in}}),}
Q ˙ = T hs ' T air,av R hs , {\displaystyle {\dot {Q}}={\frac {T_{\text{hs}}-T_{\text{air,av}}}{R_{\text{hs}}}},}
where
T air,av = T air,in + T air,out 2 . {\displaystyle T_{\text{air,av}}={\frac {T_{\text{air,in}}+T_{\text{air,out}}}{2}}.}
m ˙ {\displaystyle {\dot {m}}}
c p , in {\displaystyle c_{p,{\text{in}}}}
R hs {\displaystyle {R_{\text{hs}}}}
Using the mean air temperature is an assumption that is valid for relatively short heat sinks. When compact heat exchangers are calculated, the logarithmic mean air temperature is used.
The above equations show that:
[
2]
Natural convection requires free flow of air over the heat sink. If fins are not aligned vertically, or if fins are too close together to allow sufficient air flow between them, the efficiency of the heat sink will decline.
[
edit
]
Power transistor heat sinks. Left for TO-3 package, right for TO-220 package, middle for two TO-220.[
edit
]
For semiconductor devices used in a variety of consumer and industrial electronics, the idea of thermal resistance simplifies the selection of heat sinks. The heat flow between the semiconductor die and ambient air is modeled as a series of resistances to heat flow; there is a resistance from the die to the device case, from the case to the heat sink, and from the heat sink to the ambient air. The sum of these resistances is the total thermal resistance from the die to the ambient air. Thermal resistance is defined as temperature rise per unit of power, analogous to electrical resistance, and is expressed in units of degrees Celsius per watt (°C/W). If the device dissipation in watts is known, and the total thermal resistance is calculated, the temperature rise of the die over the ambient air can be calculated.
The idea of thermal resistance of a semiconductor heat sink is an approximation. It does not take into account non-uniform distribution of heat over a device or heat sink. It only models a system in thermal equilibrium and does not take into account the change in temperatures with time. Nor does it reflect the non-linearity of radiation and convection with respect to temperature rise. However, manufacturers tabulate typical values of thermal resistance for heat sinks and semiconductor devices, which allows selection of commercially manufactured heat sinks to be simplified.[3]
Commercial extruded aluminium heat sinks have a thermal resistance (heat sink to ambient air) ranging from 0.4 °C/W for a large sink meant for TO-3 devices, up to as high as 85 °C/W for a clip-on heat sink for a TO-92 small plastic case.[3] The popular 2N power transistor in a TO-3 case has an internal thermal resistance from junction to case of 1.52 °C/W.[4] The contact between the device case and heat sink may have a thermal resistance between 0.5 and 1.7 °C/W, depending on the case size and use of grease or insulating mica washer.[3]
[
edit
]
The materials for heat sink applications should have high heat capacity and thermal conductivity in order to absorb more heat energy without shifting towards a very high temperature and transmit it to the environment for efficient cooling.[5] The most common heat sink materials are aluminium alloys.[6] Aluminium alloy has one of the higher thermal conductivity values at 229 W/(m·K) and heat capacity of 922 J/(kg·K),[7] but is mechanically soft. Aluminium alloys (low-stress), , and are commonly used, with thermal conductivity values of 166 and 201 W/(m·K) respectively. The values depend on the temper of the alloy. One-piece aluminium heat sinks can be made by extrusion, casting, skiving or milling.
Copper has excellent heat-sink properties in terms of its thermal conductivity, corrosion resistance, biofouling resistance, and antimicrobial resistance (see also Copper in heat exchangers). Copper has around twice the thermal conductivity of aluminium, around 400 W/(m·K) for pure copper. Its main applications are in industrial facilities, power plants, solar thermal water systems, HVAC systems, gas water heaters, forced air heating and cooling systems, geothermal heating and cooling, and electronic systems.
Copper is three times as dense[6] and more expensive than aluminium, and copper is less ductile than aluminum.[6] One-piece copper heat sinks can be made by skiving or milling. Sheet-metal fins can be soldered onto a rectangular copper body.[8][9]
[
edit
]
Fin efficiency is one of the parameters that makes a higher-thermal-conductivity material important. A fin of a heat sink may be considered to be a flat plate with heat flowing in one end and being dissipated into the surrounding fluid as it travels to the other.[10] As heat flows through the fin, the combination of the thermal resistance of the heat sink impeding the flow and the heat lost due to convection, the temperature of the fin and, therefore, the heat transfer to the fluid, will decrease from the base to the end of the fin. Fin efficiency is defined as the actual heat transferred by the fin, divided by the heat transfer were the fin to be isothermal (hypothetically the fin having infinite thermal conductivity). These equations are applicable for straight fins:[11]
η f = tanh ' ( m L c ) m L c , {\displaystyle \eta _{\text{f}}={\frac {\tanh(mL_{c})}{mL_{c}}},}
m L c = 2 h f k t f L f , {\displaystyle mL_{c}={\sqrt {\frac {2h_{\text{f}}}{kt_{\text{f}}}}}L_{\text{f}},}
where
Fin efficiency is increased by decreasing the fin aspect ratio (making them thicker or shorter), or by using a more conductive material (copper instead of aluminium, for example).
[
edit
]
Another parameter that concerns the thermal conductivity of the heat-sink material is spreading resistance. Spreading resistance occurs when thermal energy is transferred from a small area to a larger area in a substance with finite thermal conductivity. In a heat sink, this means that heat does not distribute uniformly through the heat-sink base. The spreading resistance phenomenon is shown by how the heat travels from the heat source location and causes a large temperature gradient between the heat source and the edges of the heat sink. This means that some fins are at a lower temperature than if the heat source were uniform across the base of the heat sink. This nonuniformity increases the heat sink's effective thermal resistance.
To decrease the spreading resistance in the base of a heat sink:
[
edit
]
If you want to learn more, please visit our website extruded aluminum heat sink components.
Heat-sink types: pin, straight, and flared finA pin fin heat sink is a heat sink that has pins that extend from its base. The pins can be cylindrical, elliptical, or square. A second type of heat sink fin arrangement is the straight fin. A variation on the straight fin heat sink is a cross-cut heat sink. A third type of heat sink is the flared fin heat sink, where the fins are not parallel to one another. Flaring the fins decreases flow resistance and makes more air go through the heat-sink fin channel; otherwise, more air would bypass the fins. Slanting them keeps the overall dimensions the same, but offers longer fins. Examples of the three types are shown in the image on the right.
Forghan, et al.[12] have published data on tests conducted on pin fin, straight fin, and flared fin heat sinks. They found that for low air approach velocity, typically around 1 m/s, the thermal performance is at least 20% better than straight fin heat sinks. Lasance and Eggink[13] also found that for the bypass configurations that they tested, the flared heat sink performed better than the other heat sinks tested.
Free-convection flow around a pin-fin heat sinkGenerally, the more surface area a heat sink has, the better its performance.[2] Real-world performance depends on the design and application. The concept of a pin fin heat sink is to pack as much surface area into a given volume as possible, while working in any orientation of fluid flow.[2] Kordyban[2] has compared the performance of a pin-fin and a straight-fin heat sink of similar dimensions. Although the pin-fin has 194 cm2 surface area while the straight-fin has 58 cm2, the temperature difference between the heat-sink base and the ambient air for the pin fin is 50 °C, but for the straight-fin it was 44 °C, or 6 °C better than the pin fin. Pin fin heat sink performance is significantly better than straight fins when used in their optimal application where the fluid flows axially along the pins rather than only tangentially across the pins.
Comparison of a pin-fin and straight-fin heat sink of similar dimensions[
2]
Heat-sink fin type Width [cm] Length [cm] Height [cm] Surface area [cm2] Volume [cm3] Temperature difference, Tcase ' Tair [°C] Straight 2.5 2.5 3.2 58 20 44 Pin 3.8 3.8 1.7 194 24 51 Cavities (inverted fins)[
edit
]
Cavities (inverted fins) embedded in a heat source are the regions formed between adjacent fins that stand for the essential promoters of nucleate boiling or condensation. These cavities are usually utilized to extract heat from a variety of heat-generating bodies to a heat sink.[14][15]
[
edit
]
Placing a conductive thick plate as a heat-transfer interface between a heat source and a cold flowing fluid (or any other heat sink) may improve the cooling performance. In such arrangement, the heat source is cooled under the thick plate instead of being cooled in direct contact with the cooling fluid. It is shown[citation needed] that the thick plate can significantly improve the heat transfer between the heat source and the cooling fluid by conducting the heat current in an optimal manner. The two most attractive advantages of this method are that no additional pumping power and no extra heat-transfer surface area, that is quite different from fins (extended surfaces).
[
edit
]
A server-grade flash memory card with a black heat sinkThe heat transfer from the heat sink occurs by convection of the surrounding air, conduction through the air, and radiation.
Heat transfer by radiation is a function of both the heat-sink temperature and the temperature of the surroundings that the heat sink is optically coupled with. When both of these temperatures are on the order of 0 °C to 100 °C, the contribution of radiation compared to convection is generally small, and this factor is often neglected. In this case, finned heat sinks operating in either natural-convection or forced-flow will not be affected significantly by surface emissivity.
In situations where convection is low, such as a flat non-finned panel with low airflow, radiative cooling can be a significant factor. Here the surface properties may be an important design factor. Matte-black surfaces radiate much more efficiently than shiny bare metal.[16][17] A shiny metal surface has low emissivity. The emissivity of a material is tremendously frequency-dependent and is related to absorptivity (of which shiny metal surfaces have very little). For most materials, the emissivity in the visible spectrum is similar to the emissivity in the infrared spectrum;[citation needed] however, there are exceptions ' notably, certain metal oxides that are used as "selective surfaces".
In vacuum or outer space, there is no convective heat transfer, thus in these environments, radiation is the only factor governing heat flow between the heat sink and the environment. For a satellite in space, a 100 °C (373 K) surface facing the Sun will absorb a lot of radiant heat, because the Sun's surface temperature is nearly K, whereas the same surface facing deep space will radiate a lot of heat, since deep space has an effective temperature of only several Kelvin.
[
edit
]
[
edit
]
Cooling system of an Asus GTX 650 graphics card; three heat pipes are visibleHeat dissipation is an unavoidable by-product of electronic devices and circuits.[10] In general, the temperature of the device or component will depend on the thermal resistance from the component to the environment, and the heat dissipated by the component. To ensure that the component does not overheat, a thermal engineer seeks to find an efficient heat transfer path from the device to the environment. The heat transfer path may be from the component to a printed circuit board (PCB), to a heat sink, to air flow provided by a fan, but in all instances, eventually to the environment.
Two additional design factors also influence the thermal/mechanical performance of the thermal design:
[
11]
This temperature change may be attributed to what is known as the thermal contact resistance.[
11]
Thermal interface materials (TIM) decrease the thermal contact resistance.[
edit
]
As power dissipation of components increases and component package size decreases, thermal engineers must innovate to ensure components won't overheat. Devices that run cooler last longer. A heat sink design must fulfill both its thermal as well as its mechanical requirements. Concerning the latter, the component must remain in thermal contact with its heat sink with reasonable shock and vibration. The heat sink could be the copper foil of a circuit board, or a separate heat sink mounted onto the component or circuit board. Attachment methods include thermally conductive tape or epoxy, wire-form z clips, flat spring clips, standoff spacers, and push pins with ends that expand after installing.
Thermally conductive tape is one of the most cost-effective heat sink attachment materials.[18] It is suitable for low-mass heat sinks and for components with low power dissipation. It consists of a thermally conductive carrier material with a pressure-sensitive adhesive on each side.
This tape is applied to the base of the heat sink, which is then attached to the component. Following are factors that influence the performance of thermal tape:[18]
Epoxy is more expensive than tape, but provides a greater mechanical bond between the heat sink and component, as well as improved thermal conductivity.[18] The epoxy chosen must be formulated for this purpose. Most epoxies are two-part liquid formulations that must be thoroughly mixed before being applied to the heat sink, and before the heat sink is placed on the component. The epoxy is then cured for a specified time, which can vary from 2 hours to 48 hours. Faster cure time can be achieved at higher temperatures. The surfaces to which the epoxy is applied must be clean and free of any residue.
The epoxy bond between the heat sink and component is semi-permanent/permanent.[18] This makes re-work very difficult and at times impossible. The most typical damage caused by rework is the separation of the component die heat spreader from its package.
A pin fin heat sink with a Z-clip retainerMore expensive than tape and epoxy, wire form z-clips attach heat sinks mechanically. To use the z-clips, the printed circuit board must have anchors. Anchors can be either soldered onto the board, or pushed through. Either type requires holes to be designed into the board. The use of RoHS solder must be allowed for because such solder is mechanically weaker than traditional Pb/Sn solder.
To assemble with a z-clip, attach one side of it to one of the anchors. Deflect the spring until the other side of the clip can be placed in the other anchor. The deflection develops a spring load on the component, which maintains very good contact. In addition to the mechanical attachment that the z-clip provides, it also permits using higher-performance thermal interface materials, such as phase change types.[18]
Two heat sink attachment methods, namely the maxiGRIP (left) and Talon Clip (right)Available for processors and ball grid array (BGA) components, clips allow the attachment of a BGA heat sink directly to the component. The clips make use of the gap created by the ball grid array (BGA) between the component underside and PCB top surface. The clips therefore require no holes in the PCB. They also allow for easy rework of components.
A pair of push pinsFor larger heat sinks and higher preloads, push pins with compression springs are very effective.[18] The push pins, typically made of brass or plastic, have a flexible barb at the end that engages with a hole in the PCB; once installed, the barb retains the pin. The compression spring holds the assembly together and maintains contact between the heat sink and component. Care is needed in selection of push pin size. Too great an insertion force can result in the die cracking and consequent component failure.
For very large heat sinks, there is no substitute for the threaded standoff and compression spring attachment method.[18] A threaded standoff is essentially a hollow metal tube with internal threads. One end is secured with a screw through a hole in the PCB. The other end accepts a screw which compresses the spring, completing the assembly. A typical heat sink assembly uses two to four standoffs, which tends to make this the most costly heat sink attachment design. Another disadvantage is the need for holes in the PCB.
Summary of heat sink attachment methods[
18]
Method Pros Cons Cost Thermal tape Easy to attach. Inexpensive. Cannot provide mechanical attachment for heavier heat sinks or for high vibration environments. Surface must be cleaned for optimal adhesion. Moderate to low thermal conductivity. Very low Epoxy Strong mechanical adhesion. Relatively inexpensive. Makes board rework difficult since it can damage component. Surface must be cleaned for optimal adhesion. Very low Wire form Z-clips Strong mechanical attachment. Easy removal/rework. Applies a preload to the thermal interface material, improving thermal performance. Requires holes in the board or solder anchors. More expensive than tape or epoxy. Custom designs. Low Clip-on Applies a preload to the thermal interface material, improving thermal performance. Requires no holes or anchors. Easy removal/rework. Must have "keep out" zone around the BGA for the clip. Extra assembly steps. Low Push pin with compression springs Strong mechanical attachment. Highest thermal interface material preload. Easy removal and installation. Requires holes in the board which increases complexity of traces in PCB. Moderate Stand-offs with compression springs Strongest mechanical attachment. Highest preload for the thermal interface material. Ideal for large heat sinks. Requires holes in the board which increases complexity of trace layout. Complicated assembly. High[
edit
]
Thermal conductivity and the interface resistance form part of the thermal interface resistance of a thermal interface material.Thermal contact resistance occurs due to the voids created by surface roughness effects, defects and misalignment of the interface. The voids present in the interface are filled with air. Heat transfer is therefore due to conduction across the actual contact area and to conduction (or natural convection) and radiation across the gaps.[11] If the contact area is small, as it is for rough surfaces, the major contribution to the resistance is made by the gaps.[11] To decrease the thermal contact resistance, the surface roughness can be decreased while the interface pressure is increased. However, these improving methods are not always practical or possible for electronic equipment. Thermal interface materials (TIM) are a common way to overcome these limitations.
Properly applied thermal interface materials displace the air that is present in the gaps between the two objects with a material that has a much-higher thermal conductivity. Air has a thermal conductivity of 0.022 W/(m·K)[19] while TIMs have conductivities of 0.3 W/(m·K)[20] and higher.
When selecting a TIM, care must be taken with the values supplied by the manufacturer. Most manufacturers give a value for the thermal conductivity of a material. However, the thermal conductivity does not take into account the interface resistances. Therefore, if a TIM has a high thermal conductivity, it does not necessarily mean that the interface resistance will be low.
Selection of a TIM is based on three parameters: the interface gap which the TIM must fill, the contact pressure, and the electrical resistivity of the TIM. The contact pressure is the pressure applied to the interface between the two materials. The selection does not include the cost of the material. Electrical resistivity may be important depending upon electrical design details.
Selection based on interface gap[
20]
Interface gap values Products types available < 0.05 mm < 2 mil Thermal grease, epoxy, phase change materials 0.05'0.1 mm 2'5 mil Phase change materials, polyimide, graphite or aluminium tapes 0.1'0,5 mm 5'18 mil Silicone-coated fabrics > 0.5 mm > 18 mil Gap fillers Selection based on contact pressure[
20]
Contact pressure scale Typical pressure ranges Product types available Very low < 70 kPa Gap fillers Low < 140 kPa Thermal grease, epoxy, polyimide, graphite or aluminium tapes High 2 MPa Silicone-coated fabrics TIM application notes based on product type Product type Application notes Thermal performance Thermal paste Messy. Labor-intensive. Relatively long assembly time. ++++ Epoxy Creates "permanent" interface bond. ++++ Phase change Allows for pre-attachment. Softens and conforms to interface defects at operational temperatures. Can be repositioned in field. ++++ Thermal tapes, including graphite, polyimide, and aluminium tapes Easy to apply. Some mechanical strength. +++ Silicone coated fabrics Provide cushioning and sealing while still allowing heat transfer. + Gap filler Can be used to thermally couple differing-height components to a heat spreader or heat sink. Naturally tacky. ++[
edit
]
Light-emitting diode (LED) performance and lifetime are strong functions of their temperature.[21] Effective cooling is therefore essential. A case study of a LED based downlighter shows an example of the calculations done in order to calculate the required heat sink necessary for the effective cooling of lighting system.[22] The article also shows that in order to get confidence in the results, multiple independent solutions are required that give similar results. Specifically, results of the experimental, numerical and theoretical methods should all be within 10% of each other to give high confidence in the results.
[
edit
]
Temporary heat sinks are sometimes used while soldering circuit boards, preventing excessive heat from damaging sensitive nearby electronics. In the simplest case, this means partially gripping a component using a heavy metal crocodile clip, hemostat, or similar clamp. Modern semiconductor devices, which are designed to be assembled by reflow soldering, can usually tolerate soldering temperatures without damage. On the other hand, electrical components such as magnetic reed switches can malfunction if exposed to hotter soldering irons, so this practice is still very much in use.[23]
[
edit
]
In general, a heat sink performance is a function of material thermal conductivity, dimensions, fin type, heat transfer coefficient, air flow rate, and duct size. To determine the thermal performance of a heat sink, a theoretical model can be made. Alternatively, the thermal performance can be measured experimentally. Due to the complex nature of the highly 3D flow in present applications, numerical methods or computational fluid dynamics (CFD) can also be used. This section will discuss the aforementioned methods for the determination of the heat sink thermal performance.
[
edit
]
Sketch of a heat sink with equivalent thermal resistances Thermal resistance and heat transfer coefficient plotted against flow rate for the specific heat sink design used in.[
24]
The data was generated using the equations provided in the article. The data shows that for an increasing air flow rate, the thermal resistance of the heat sink decreases.One of the methods to determine the performance of a heat sink is to use heat transfer and fluid dynamics theory. One such method has been published by Jeggels, et al.,[24] though this work is limited to ducted flow. Ducted flow is where the air is forced to flow through a channel which fits tightly over the heat sink. This makes sure that all the air goes through the channels formed by the fins of the heat sink. When the air flow is not ducted, a certain percentage of air flow will bypass the heat sink. Flow bypass was found to increase with increasing fin density and clearance, while remaining relatively insensitive to inlet duct velocity.[25]
The heat sink thermal resistance model consists of two resistances, namely the resistance in the heat sink base, R b {\displaystyle R_{b}} , and the resistance in the fins, R f {\displaystyle R_{f}} . The heat sink base thermal resistance, R b {\displaystyle R_{b}} , can be written as follows if the source is a uniformly applied the heat sink base. If it is not, then the base resistance is primarily spreading resistance:
R b = t b k A b {\displaystyle R_{b}={\frac {t_{b}}{kA_{b}}}}
where t b {\displaystyle t_{b}} is the heat sink base thickness, k {\displaystyle k} is the heat sink material thermal conductivity and A b {\displaystyle A_{b}} is the area of the heat sink base.
The thermal resistance from the base of the fins to the air, R f {\displaystyle R_{f}} , can be calculated by the following formulas:
R f = 1 n h f W f ( t f + 2 η f L f ) {\displaystyle R_{f}={\frac {1}{nh_{f}W_{f}\left(t_{f}+2\eta _{f}L_{f}\right)}}}
η f = tanh ' m L c m L c {\displaystyle \eta _{f}={\frac {\tanh {mL_{c}}}{mL_{c}}}}
[
11]
(6)m L c = 2 h f k t f L f {\displaystyle mL_{c}={\sqrt {\frac {2h_{f}}{kt_{f}}}}L_{f}}
[
11]
(7)D h = 4 A c h P c h {\displaystyle D_{h}={\frac {4A_{ch}}{P_{ch}}}}
R e = 4 G ˙ ρ n π D h μ {\displaystyle Re={\frac {4{\dot {G}}\rho }{n\pi D_{h}\mu }}}
f = ( 0.79 ln ' R e ' 1.64 ) ' 2 {\displaystyle f=(0.79\ln Re-1.64)^{-2}}
[
26]
(10)N u = ( f / 8 ) ( R e ' ) P r 1 + 12.7 ( f / 8 ) 0.5 ( P r 2 3 ' 1 ) {\displaystyle Nu={\frac {(f/8)(Re-)Pr}{1+12.7(f/8)^{0.5}(Pr^{\frac {2}{3}}-1)}}}
[
26]
(11)h f = N u k a i r D h {\displaystyle h_{f}={\frac {Nuk_{air}}{D_{h}}}}
ρ = P a t m R a T i n {\displaystyle \rho ={\frac {P_{atm}}{R_{a}T_{in}}}}
The flow rate can be determined by the intersection of the heat sink system curve and the fan curve. The heat sink system curve can be calculated by the flow resistance of the channels and inlet and outlet losses as done in standard fluid mechanics text books, such as Potter, et al.[27] and White.[28]
Once the heat sink base and fin resistances are known, then the heat sink thermal resistance, R h s {\displaystyle R_{hs}} can be calculated as:
R h s = R b + R f {\displaystyle R_{hs}=R_{b}+R_{f}}
Using the equations 5 to 13 and the dimensional data in,[24] the thermal resistance for the fins was calculated for various air flow rates. The data for the thermal resistance and heat transfer coefficient are shown in the diagram, which shows that for an increasing air flow rate, the thermal resistance of the heat sink decreases.
[
edit
]
Experimental tests are one of the more popular ways to determine the heat sink thermal performance. In order to determine the heat sink thermal resistance, the flow rate, input power, inlet air temperature and heat sink base temperature need to be known. Vendor-supplied data is commonly provided for ducted test results.[29] However, the results are optimistic and can give misleading data when heat sinks are used in an unducted application. More details on heat sink testing methods and common oversights can be found in Azar, et al.[29]
[
edit
]
Radial heat sink with thermal profile and swirling forced convection flow trajectories predicted using a CFD analysis packageIn industry, thermal analyses are often ignored in the design process or performed too late ' when design changes are limited and become too costly.[10] Of the three methods mentioned in this article, theoretical and numerical methods can be used to determine an estimate of the heat sink or component temperatures of products before a physical model has been made. A theoretical model is normally used as a first order estimate. Online heat sink calculators[30] can provide a reasonable estimate of forced and natural convection heat sink performance based on a combination of theoretical and empirically derived correlations. Numerical methods or computational fluid dynamics (CFD) provide a qualitative (and sometimes even quantitative) prediction of fluid flows.[31][32] What this means is that it will give a visual or post-processed result of a simulation, like the images in figures 16 and 17, and the CFD animations in figure 18 and 19, but the quantitative or absolute accuracy of the result is sensitive to the inclusion and accuracy of the appropriate parameters.
CFD can give an insight into flow patterns that are difficult, expensive or impossible to study using experimental methods.[31] Experiments can give a quantitative description of flow phenomena using measurements for one quantity at a time, at a limited number of points and time instances. If a full-scale model is not available or not practical, scale models or dummy models can be used. The experiments can have a limited range of problems and operating conditions. Simulations can give a prediction of flow phenomena using CFD software for all desired quantities, with high resolution in space and time and virtually any problem and realistic operating conditions. However, if critical, the results may need to be validated.[2]
Pin fin heat sink with thermal profile and free convection flow trajectories predicted using a CFD analysis package 38 mm diameter by 50 mm tall pin fin heat sink with thermal profile and swirling animated forced convection flow trajectories from a vaneaxial fan, predicted using a CFD analysis package 60 mm by 60 mm by 10 mm straight finned heat sink with thermal profile and swirling animated forced convection flow trajectories from a tubeaxial fan, predicted using a CFD analysis package[
edit
]
[
edit
]
Contact us to discuss your requirements of aluminum profile tubing. Our experienced sales team can help you identify the options that best suit your needs.