Colleagues,
I am a bridge designer so I deal with steel and concrete and big time loads so I just don't have a feel for typical residential wood design. I offered to help a buddy design or scope out what it would take to build a shed on his property. He has some grand ideas and I'm trying to help him keep his perspective.
If someone could help me understand why I am seeing a much larger member size for joists in this problem, I'd appreciate the insight.
The building will be 24 x 16 in plan with the width as you face the shed being the smaller dimension, 16 feet. He wants to build a second floor for storing material and some tools (ladders and such) and he would like the second floor to cover the back half of the shed, 12 feet deep and 16 feet wide. He hopes to avoid any columns.
I estimated the plywood floor to require 5/8" plywood if we used joists on 16" centers. When computing the joist size I believed that if we used a strong edge beam, we might be able to span the 12 foot direction with the 2x joists. I thought a 12 feet span at 16" centers would be achieved with a 2x8 easily but maybe we could get away with just 2x6 even at 100psf live load. Well I did the calcs and I was nowhere near a 2x6 so I thought what did I screw up. I went to look it up in a table online for reference and the table indicated a 2x10 would be needed for 40 psf live load and I had hoped to accommodate 100 psf.
If my description is clear, I would appreciate any insight as to how a 2x10 is required for 16" centers and a 12 feet span for a joist. Thanks in advance for your help.
For more information, please visit XINFUSHI.
I built a house last year and used them. I did not want a bouncy floor either and if designed right, it won't be bouncy. I sized them myself on the plans from span tables available. I am a mechanical engineer but didn't try to do real calcs as that is done in the span tables. My builder thought I over-sized them so we ran it by the civil engineer at the supplier and he agreed with me. So, left to some builders and others, I could see how you could end up with a structurally safe but bouncy floor. The floor is flat as a flitter (that might be a local saying). I am happy with them. If you use them make sure the builder installs "squash blocks" at all load bearing points above which is typically the ends where exterior walls are and other interior load bearing areas. They should not pass framing inspection without the squash blocks. They are readily available in stock lengths and delivered faster than floor trusses. The negative compared to trusses is running duct work, pipe, wire, etc through them. I would not frame with 2X lumber again for floors.
I will add that mine are above minimum allowable in the tables. They are 14 and a fraction tall, on 16" centers, with a large LVL beam at midspan and span from end to center beam is about 16'. The floor is glued and screwed with 3/4" Advantech subfloor. We have been here about 18 months now and the other day my wife commented "have you noticed there aren't any floor squeaks anywhere". The house we moved from was 2x12 joist, glued and nailed plywood subfloor with hardwood, built in and had floor squeaks lots of places.