I work for a motor shop. I do this all the time. Used just about every crimped.

So the way UL works is you are supposed to use the crimper that the manufacturer specifies. Of course few electricians ever do that. And by UL crimpers have a list of lugs they work with. There are “universal” crimpers though that work with a half dozen or more manufacturer lugs. I will also say right up front do NOT expect everything to always work as marked. Even with the correct die, correct wire, correct crimper sometimes you get over/under crimping. You need to recognize this and adjust.

Look at the crimps. For you this may be less critical but I’m doing a lot of medium voltage (2.4 kv to 35 kv) jobs. Especially at 15 kv and above you need to stay close to “round” and file off every sharp edge. So your choices are indent crimp, quad indent, and hex crimp. Do hex crimps. Even on lower voltages they just look more professional than a big old dent in the lug with the wire squeezed off to the sides with who knows what pressure. That looks OK at #14 but it looks amateur at 350, and the price is the same,

I’m going to tell you right now though that there are Chinese made crimpers on the market. Temco for instance sells one in a blue case and Amazon sells the yellow case one. Neither is UL. The yellow one is metric...don’t buy. These things are about $100. They are due types with hex dies. We’ve used them for years with no problems. It’s as cheap as hand crimps. I’ve never had an inspector fail these. Mostly they’re more impressed with crimped on bolted lugs instead of mechanical crap. It is a hand pumped hydraulic crimper. It obsoletes all the other low end tools, we have an old one, at least ten years old, that we finally retired and got 3 more. I’m a big fan of avoiding questionable products from China. This isn’t one of those.

Going past that all crimpers work one of two ways. Either they use fixed dies and squeeze until the dies touch (or indent hits a stop) or they have a pressure relief. 6 ton dies relieve at 5000 PSI. 12 ton dies at 10,000 PSI. The 6 ton dies stop at 350. Get the 12 ton. You will get 500 MCM jobs once in a while. Don’t limit yourself.

You can rent a $1500 pump and a cheap hydraulic crimper or use a mechanically pumped or electrically pumped all in one. The pump system is fast but best for big jobs.

The motorized ones are AWESOME. This is what all the line crews use. The best two are the Greenlee Gator ECCX Pro series and the Ridgid RE 6. For two reasons. First they are truly universal which is why I would ignore the cheaper Dewalt and Milwaukee. In one motorized crimper you can cut, do knockouts, and crimp, it makes quick work of any crimp job. Second reason is these things are used by all the line crews. Which means you can often get one on EBay for around $1500 with some dies. It will probably be missing a few. Die sets are common and you can fill a couple gaps to get up to speed easily at under $2000. Plus do motorized cutting and knockouts...I love mine. I’ve got an ECCX Pro with all the bells and whistles.

Ignoring utility dies (C, O, W) there is one universal 12 ton die, U dies. They work on Milwaukee, Greenlee, etc. But the dies themselves run about twice the price of proprietary die sets such as Greenlee KC series. So see my previous comment. Dies last almost forever. Get the proprietary set and save the money. The RE-6 and ECCX Pro can use either with adapters.

Another option is dieless. These aren’t motorized but it takes the die issue out of it. You just pump until they pop. Anderson makes a nice hex crimp one and I think T&B private labels it. They are very nice and the shop has a couple. But the crimp heads are enormous. It’s hard to get into some peckerheads and tight boxes with it. Plus it doesn’t cut so back to ratchet crimpers. And add 1000-2000 to the die crimper prices WITH dies.

Other good points about this approach. On the larger lugs especially with emergency jobs you are going to struggle to get lugs quickly if you don’t stock your own. And I have thousands wrapped up in lug inventory too in the truck. So you can buy the T&B crimper for instance but what if the supply house that has the 350s you really need only has Ilsco or Burndy? The truth is your T&B crimper will work just fine but I like the idea of truly universal.

Want more information on Indented 3 Wire Strand? Feel free to contact us.

 

Are you interested in learning more about Biodegradable Can Liner? Contact us today to secure an expert consultation!

Do-It-Yourself Wiring the Home With Ethernet: What to Buy

Post by TheDDC » Sun Sep 02, 2018 8:21 pm



Cabling choice - I chose Cat6 when I did this ten years ago in my place. I just helped a friend run Cat 6a in his place. The real advantage with 6a is the shielding if you are running near electric wires, but even then it's overkill most likely. Preterminated cabling is nice. However, you would need a significantly larger diameter hole if you were running 2+ cables anywhere. I have also discovered more than enough preterminated cables from monoprice that were bad (only negotiated to 100/full instead of 1000/full). I would not run condutit to each location unless new construction and the walls are open. Even commercial construction does not deem that as "normal".

Number of cables - minimum two per single gang box. My office has four.

Mesh networks - Only as good as the 5G channel(s) with least interference, which could be few/spotty depending on your area. I would not rely "clean air" to service internet needs, personally. Go with some UniFi APs (I run 2 x UAP-AC-HDs, ceiling mounted) with ethernet backhauls.

Switches - My switch(es) support PoE+ and can go up to 30W per port.

I am most likely going to add another IDF in my attic so I will be running OM4 fiber. If you are considering adding a switch in the attic I would run fiber through your conduit.

Tools - Stripper, Ideal brand crimper (don't rely on the stripper built into it), screwdrivers, 5' fish rods, fish tape. I personally like the reciprocating saw for cutting in boxes.

I prefer single gang open back wall caddies and not the blue plastic electrical caddies (old work boxes) due to the space allowed in the box for slack. I made the mistake of using the blue ones and will most likely go with the open back ones during the next upgrade, or just drill giant holes into the back of them and not mess with the tabs at the top. Live and learn.

A few hole saw wood bits (.5" up to 1") will help.

Would love to hear how this goes! I ran at least two Cat6 drops to every room in the house (sans bathrooms) and would not regret it to this day. The only drops that have not gotten used have been in the girls' room and that's only because they are under 5.

-TheDDC

Nice to see this thread on here from a fellow geek. I would recommend running conduit up to your attic if possible. I ran 2 x .75" orange flex conduits up when I first moved into my house. This allowed me to install 2 x Cat6 drops into every room. I ran cabling up from basement to first floor and then from attic to second floor all because of the decision to run the conduit. If you were to find a good place to run the bundle up to the attic and drop down above the ceiling plate that would be the easiest. I did not need to patch a single thing that way.Cabling choice - I chose Cat6 when I did this ten years ago in my place. I just helped a friend run Cat 6a in his place. The real advantage with 6a is the shielding if you are running near electric wires, but even then it's overkill most likely. Preterminated cabling is nice. However, you would need a significantly larger diameter hole if you were running 2+ cables anywhere. I have also discovered more than enough preterminated cables from monoprice that were bad (only negotiated to 100/full instead of 1000/full). I would not run condutit to each location unless new construction and the walls are open. Even commercial construction does not deem that as "normal".Number of cables - minimum two per single gang box. My office has four.Mesh networks - Only as good as the 5G channel(s) with least interference, which could be few/spotty depending on your area. I would not rely "clean air" to service internet needs, personally. Go with some UniFi APs (I run 2 x UAP-AC-HDs, ceiling mounted) with ethernet backhauls.Switches - My switch(es) support PoE+ and can go up to 30W per port.I am most likely going to add another IDF in my attic so I will be running OM4 fiber. If you are considering adding a switch in the attic I would run fiber through your conduit.Tools - Stripper, Ideal brand crimper (don't rely on the stripper built into it), screwdrivers, 5' fish rods, fish tape. I personally like the reciprocating saw for cutting in boxes.I prefer single gang open back wall caddies and not the blue plastic electrical caddies (old work boxes) due to the space allowed in the box for slack. I made the mistake of using the blue ones and will most likely go with the open back ones during the next upgrade, or just drill giant holes into the back of them and not mess with the tabs at the top.Live and learn.A few hole saw wood bits (.5" up to 1") will help.Would love to hear how this goes! I ran at least two Cat6 drops to every room in the house (sans bathrooms) and would not regret it to this day. The only drops that have not gotten used have been in the girls' room and that's only because they are under 5.-TheDDC